×

Enquiry Form

info@labtron.us

Benchtop Multi-parameter Water Quality Meter

Benchtop Multi-parameter Water Quality Meter LMPWM-A30

  • pH Mode :
    pH range -2.00 to 20.00 pH
    pH Accuracy ± 0.002 pH
    pH Resolution 0.1/0.01/0.001 pH, selectable
    pH Calibration Points 1 to 5 Points
    pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
  • mV Mode :
    mV Range -1999.9 to 1999.9 mV
    mV Accuracy ± 0.2 mV
    mV Resolution 0.1/1 mV, selectable
    mV Calibration Points 1 Point
  • Conductivity Mode :
    Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
    Conductivity Accuracy ± 0.5% F.S.
    Conductivity Resolution 0.01/0.1/1
    Conductivity Calibration Points 1 to 5 Points
    Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
    Conductivity Temperature coefficient 0.0 to 10.0 %/°C
    Compensation mode Linear or Pure Water
    Cell Constant K=0.1, 1, 10 or Custom
    Reference temperature 20 or 25°C
  • TDS Mode :
    TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
    TDS Accuracy ± 1 % F.S.
    TDS Factor 0.1  to 1.0 (default 0.5)
  • Temperature Range : 0 to 105°C, 32 to 221°F

Benchtop Multi-parameter Water Quality Meter LMPWM-A31

  • pH Mode :
    pH range -2.00 to 20.00 pH
    pH Accuracy ± 0.002 pH
    pH Resolution 0.1/0.01/0.001 pH, selectable
    pH Calibration Points 1 to 5 Points
    pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
  • mV Mode :
    mV Range -1999.9 to 1999.9 mV
    mV Accuracy ± 0.2 mV
    mV Resolution 0.1/1 mV, selectable
    mV Calibration Points 1 Point
  • Conductivity Mode :
    Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
    Conductivity Accuracy ± 0.5% F.S.
    Conductivity Resolution 0.01/0.1/1
    Conductivity Calibration Points 1 to 5 Points
    Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
    Conductivity Temperature coefficient 0.0 to 10.0 %/°C
    Compensation mode Linear or Pure Water
    Cell Constant K=0.1, 1, 10 or Custom
    Reference temperature 20 or 25°C
  • TDS Mode :
    TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
    TDS Accuracy ± 1 % F.S.
    TDS Factor 0.1  to 1.0 (default 0.5)
  • Salinity Mode :
    Salinity Range 0 to 10 ppt (maximum 80 ppt)
    Salinity Accuracy ± 1 % F.S.
    Measurement modes Seawater or practical salinity

Benchtop Multi-parameter Water Quality Meter LMPWM-A32

  • pH Mode :
    pH range -2.00 to 20.00 pH
    pH Accuracy ± 0.002 pH
    pH Resolution 0.1/0.01/0.001 pH, selectable
    pH Calibration Points 1 to 5 Points
    pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
  • mV Mode :
    mV Range -1999.9 to 1999.9 mV
    mV Accuracy ± 0.2 mV
    mV Resolution 0.1/1 mV, selectable
    mV Calibration Points 1 Point
  • Conductivity Mode :
    Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
    Conductivity Accuracy ± 0.5% F.S.
    Conductivity Resolution 0.01/0.1/1
    Conductivity Calibration Points 1 to 5 Points
    Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
    Conductivity Temperature coefficient 0.0 to 10.0 %/°C
    Compensation mode Linear or Pure Water
    Cell Constant K=0.1, 1, 10 or Custom
    Reference temperature 20 or 25°C
  • Dissolved Oxygen Mode :
    Dissolved Oxygen Range 0.00 to 20.00 mg/ L
    Dissolved Oxygen Accuracy ± 0.2 mg/ L
    Dissolved Oxygen Resolution 0.1/ 0.01 mg/ L, selectable
    Dissolved Oxygen Calibration Points 1 or 2 Points
    % Saturation Range 0.0 to 200.0 % with ± 2 % accuracy
    Pressure correction 60 to 112.5 kPa, 450 to 850 mmHg
    Salinity correction 0 to 50 g/ L
  • Temperature Range : 0 to 105°C, 32 to 221°F
Benchtop Multi-parameter Water Quality Meter LMPWM-A40
  • pH Mode :
    pH range -2.00 to 20.00 pH
    pH Accuracy ± 0.002 pH
    pH Resolution 0.1/0.01/0.001 pH, selectable
    pH Calibration Points 1 to 5 Points
    pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
  • ORP Mode :
    mV Range ± 2000 mV
    mV Accuracy ± 0.2 mV
    mV Resolution 0.1 mV, selectable
    mV Calibration Points 1 Point, only for relative mode
  • Ion Mode :
    Ion measurement range 0.01 to 30000 ppm, mg/l, mol/l, mmol/l (refer Range of ion selection)
    Ion measurement accuracy ±0.5% F.S (Monovalent), ±1% F.S (Divalent)
    Ion measurement resolution 0.001/0.01/0.1/1
    Ion measurement calibration points 2 to 5 points
    Ion measurement calibration solutions 0.001/0.01/0.1/1/10/100/1000/10000 ppm, mg/L, mol/L
    Ion measurement methods Direct reading, Known addition, Known subtraction, Sample addition, Sample subtraction
  • Water Hardness Mode :
    Water hardness measurement range 0.05-200mmol/L, 0-1120°dH, 0-1404°e, 0-2000°fH, 0-8000mg/L (Ca2+), 0~19999mg/L (CaCO3)
    Water hardness measurement accuracy ±1% F.S
    Water hardness measurement resolution 0.001/0.01/0.1/1
    Water hardness calibration points 2 to 5 points
    Water hardness calibration solutions 0.01/0.1/1/10/100 mmol/L
  • Temperature Mode :
    Temperature measurement range 0 to 105°, 32 to 212°F
    Temperature measurement accuracy ± 0.5°C, ± 0.9°F
    Temperature measurement resolution 0.1°C, 0.1°F
    Temperature measurement calibration points 1 point