Portable Conductivity Meter LPCM-A10

  • Conductivity : <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Conductivity measurement range</strong></td><td>0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm</td></tr><tr><td><strong>Conductivity accuracy</strong></td><td>±0.5% F.S</td></tr><tr><td><strong>Conductivity calibration points</strong></td><td>1 to 3 points</td></tr><tr><td><strong>Conductivity calibration solutions</strong></td><td>10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom</td></tr><tr><td><strong>Conductivity resolution</strong></td><td>0.001, 0.01, 0.1, 1</td></tr></table>
  • Temperature : <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Temperature measuring range</strong></td><td>0 105 °C, 32 to 221 °F</td></tr><tr><td><strong>Temperature measuring accuracy</strong></td><td>± °0.5 C, ± 0.9 °F</td></tr><tr><td><strong>Temperature calibration points</strong></td><td>1 point</td></tr><tr><td><strong>Temperature resolution</strong></td><td>0.1 °C, 0.1 °F</td></tr></table>
  • Temperature compensation : 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
  • Temperature coefficient : Linear
  • Reference temperature : 25 °C

Portable Conductivity Meter LPCM-A11

  • Conductivity : <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Conductivity measurement range</strong></td><td>0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm</td></tr><tr><td><strong>Conductivity accuracy</strong></td><td>±0.5% F.S</td></tr><tr><td><strong>Conductivity calibration points</strong></td><td>1 to 5 points</td></tr><tr><td><strong>Conductivity calibration solutions</strong></td><td>10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom</td></tr><tr><td><strong>Conductivity resolution</strong></td><td>0.001, 0.01, 0.1, 1</td></tr></table>
  • TDS : <table class="table table-striped table-bordered table-responsive"><tr><td><strong>TDS range</strong></td><td>0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)</td></tr><tr><td><strong>TDS accuracy</strong></td><td>±1 % F.S</td></tr><tr><td><strong>TDS factor</strong></td><td>0.01 to 1.00 (Default 0.5)</td></tr><tr><td><strong>TDS resolution</strong></td><td>0.01, 0.1, 1</td></tr></table>
  • Temperature : <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Temperature measuring range</strong></td><td>0 105 °C, 32 to 221 °F</td></tr><tr><td><strong>Temperature measuring accuracy</strong></td><td>± °0.5 C, ± 0.9 °F</td></tr><tr><td><strong>Temperature calibration points</strong></td><td>1 point</td></tr><tr><td><strong>Temperature resolution</strong></td><td>0.1 °C, 0.1 °F</td></tr></table>
  • Temperature compensation : 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
  • Temperature coefficient : Linear and Pure water compensation

Portable Conductivity Meter LPCM-A12

  • Conductivity : <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Conductivity measurement range</strong></td><td>0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm</td></tr><tr><td><strong>Conductivity accuracy</strong></td><td>±0.5% F.S</td></tr><tr><td><strong>Conductivity calibration points</strong></td><td>1 to 5 points</td></tr><tr><td><strong>Conductivity calibration solutions</strong></td><td>10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom</td></tr><tr><td><strong>Conductivity resolution</strong></td><td>0.001, 0.01, 0.1, 1</td></tr></table>
  • Salinity : <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Salinity range</strong></td><td>0.00 to 80.00 ppt, 0.00 to 42.00 psu</td></tr><tr><td><strong>Salinity accuracy</strong></td><td>±1% F.S</td></tr><tr><td><strong>Salinity measurement modes</strong></td><td>Practical Salinity (psu) or Natural Seawater (ppt)</td></tr><tr><td><strong>Salinity resolution</strong></td><td>0.01, 0.1, 1</td></tr></table>
  • Temperature : <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Temperature measuring range</strong></td><td>0 105 °C, 32 to 221 °F</td></tr><tr><td><strong>Temperature measuring accuracy</strong></td><td>± °0.5 C, ± 0.9 °F</td></tr><tr><td><strong>Temperature calibration points</strong></td><td>1 point</td></tr><tr><td><strong>Temperature resolution</strong></td><td>0.1 °C, 0.1 °F</td></tr></table>
  • Temperature compensation : 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
  • Temperature coefficient : Linear and Pure water compensation
Portable Conductivity Meter LPCM-A13
  • Conductivity : <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Conductivity measurement range</strong></td><td>0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm</td></tr><tr><td><strong>Conductivity accuracy</strong></td><td>±0.5% F.S</td></tr><tr><td><strong>Conductivity calibration points</strong></td><td>1 to 5 points</td></tr><tr><td><strong>Conductivity calibration solutions</strong></td><td>10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom</td></tr><tr><td><strong>Conductivity resolution</strong></td><td>0.001, 0.01, 0.1, 1</td></tr></table>
  • TDS : <table class="table table-striped table-bordered table-responsive"><tr><td><strong>TDS range</strong></td><td>0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)</td></tr><tr><td><strong>TDS accuracy</strong></td><td>±1 % F.S</td></tr><tr><td><strong>TDS factor</strong></td><td>0.01 to 1.00 (Default 0.5)</td></tr><tr><td><strong>TDS resolution</strong></td><td>0.01, 0.1, 1</td></tr></table>
  • Salinity : <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Salinity range</strong></td><td>0.00 to 80.00 ppt, 0.00 to 42.00 psu</td></tr><tr><td><strong>Salinity accuracy</strong></td><td>±1% F.S</td></tr><tr><td><strong>Salinity measurement modes</strong></td><td>Practical Salinity (psu) or Natural Seawater (ppt)</td></tr><tr><td><strong>Salinity resolution</strong></td><td>0.01, 0.1, 1</td></tr></table>
  • Resistivity : <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Resistivity range</strong></td><td>0.00 to 20 MΩ</td></tr><tr><td><strong>Resistivity accuracy</strong></td><td>±1% F.S</td></tr><tr><td><strong>Resistivity resolution</strong></td><td>0.01, 0.1, 1</td></tr></table>
  • Temperature : <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Temperature measuring range</strong></td><td>0 105 °C, 32 to 221 °F</td></tr><tr><td><strong>Temperature measuring accuracy</strong></td><td>± °0.5 C, ± 0.9 °F</td></tr><tr><td><strong>Temperature calibration points</strong></td><td>1 point</td></tr><tr><td><strong>Temperature resolution</strong></td><td>0.1 °C, 0.1 °F</td></tr></table>