Autoclaves

We manufacture superior grade stainless steel laboratory and medical autoclaves which are used mainly in microbiological, pharmaceutical, clinical research laboratories as well as clinics, hospitals for effectively sterilizing liquid media, cultures, medical tools, glassware etc. Its range includes Table Top autoclave, Vertical autoclave, Horizontal autoclave and Medical autoclave.

Tabletop Laboratory Autoclave LTTA-A10

  • Capacity : 20 L
  • Sterilization Temperature : 134 °C
  • Adjustment temperature : 105 to 134 °C
  • Sterilization Pressure : 0.22 MPa
  • Number of sterilizing baskets : 3

Tabletop Laboratory Autoclave LTTA-A11

  • Capacity : 24 L
  • Sterilization Temperature : 134 °C
  • Adjustment temperature : 105 to 134 °C
  • Sterilization Pressure : 0.22 MPa
  • Number of sterilizing baskets : 3
Tabletop Laboratory Autoclave LTTA-A12
  • Capacity : 35 L
  • Sterilization Temperature : 134 °C
  • Adjustment temperature : 105 to 134 °C
  • Sterilization Pressure : 0.22 MPa
  • Number of sterilizing baskets : 4
Tabletop Laboratory Autoclave LTTA-A13
  • Capacity : 50 L
  • Sterilization Temperature : 134 °C
  • Adjustment temperature : 105 to 134 °C
  • Sterilization Pressure : 0.22 MPa
  • Number of sterilizing baskets : 4

Tabletop Laboratory Autoclave LTTA-A20

  • Capacity : 24 L
  • Sterilization Temperature : 134 °C
  • Adjustment temperature : 105 to 134 °C
  • Sterilization Pressure : 0.22 MPa
  • Number of sterilizing baskets : 3

Tabletop Laboratory Autoclave LTTA-B12

  • Capacity : 35 L
  • Sterilization Temperature : 105 °C - 134 °C
  • Sterilization Pressure : 0.22 MPa
  • Number of sterilizing baskets : 4
  • Timer Range : 0 - 99 minutes
Vertical Autoclave LVA-A10
  • Capacity : 35 L
  • Chamber Volume : 318×450 mm
  • Working Sterilization Temperature : 134°C
  • Working Sterilization Pressure : 0.22 MPa
  • Time Range : 0 to 60 mins
Vertical Autoclave LVA-A11
  • Capacity : 50 L
  • Chamber Volume : 340×550 mm
  • Working Sterilization Temperature : 134°C
  • Working Sterilization Pressure : 0.22 MPa
  • Time Range : 0 to 60 mins

Vertical Autoclave LVA-A12

  • Capacity : 75 L
  • Chamber Volume : 400×600 mm
  • Working Sterilization Temperature : 134°C
  • Working Sterilization Pressure : 0.22 MPa
  • Time Range : 0 to 60 mins

Vertical Autoclave LVA-A13

  • Capacity : 100 L
  • Chamber Volume : 440×650 mm
  • Working Sterilization Temperature : 134°C
  • Working Sterilization Pressure : 0.22 MPa
  • Time Range : 0 to 60 mins
Vertical Autoclave LVA-A14
  • Capacity : 120 L
  • Chamber Volume : 480×660 mm
  • Working Sterilization Temperature : 134°C
  • Working Sterilization Pressure : 0.22 MPa
  • Time Range : 0 to 60 mins
Vertical Autoclave LVA-A15
  • Capacity : 150 L
  • Chamber Volume : 510×740 mm
  • Working Sterilization Temperature : 134°C
  • Working Sterilization Pressure : 0.22 MPa
  • Time Range : 1 to 60 mins

Horizontal autoclave LHA-D18

  • Capacity : 120 L
  • Working temperature : 105 °C to 134 °C
  • Sterilization temperature : 139 °C
  • Sterilization pressure : 0.245 MPa
  • Working pressure : 0.22 MPa

Horizontal Autoclave LHA-I10

  • Capacity : 60 L
  • Design Temperature : 150°C
  • Design Pressure : 0.26 MPa
  • Sterilization Temperature Range : 105 to 136°C
  • Temperature Display Accuracy : 0.1°C
Horizontal Autoclave LHA-I11
  • Capacity : 80 L
  • Design Temperature : 150°C
  • Design Pressure : 0.26 MPa
  • Sterilization Temperature Range : 106 to 136°C
  • Temperature Display Accuracy : 0.1°C
Horizontal Autoclave LHA-I12
  • Capacity : 120 L
  • Design Temperature : 150°C
  • Design Pressure : 0.26 MPa
  • Sterilization Temperature Range : 107 to 136°C
  • Temperature Display Accuracy : 0.1°C

Horizontal Autoclave LHA-I14

  • Capacity : 180 L
  • Design Temperature : 150°C
  • Design Pressure : 0.26 MPa
  • Sterilization Temperature Range : 108 to 136°C
  • Temperature Display Accuracy : 0.1°C

Horizontal Laboratory Autoclave LHA-A10

  • Capacity : 300 L
  • Sterilization Temperature : 134 °C
  • Sterilization Pressure : 0.22 Mpa
  • Timer Range : 0 - 99 minutes
  • Heat Average : ≤ ± 1 ℃
Medical Autoclave LMA-A10
  • Capacity : 14 L
  • Sterilization Time : 4 - 18 mins
  • Sterilization Temperature : 121 °C / 134 °C
  • No. of Trays : 3
  • Dry Procedure : Vacuum drying
Medical Autoclave LMA-A11
  • Capacity : 17 L
  • Sterilization Time : 4 - 18 mins
  • Sterilization Temperature : 121 °C / 134 °C
  • No. of Trays : 3
  • Dry Procedure : Vacuum drying

Medical Autoclave LMA-A12

  • Capacity : 23 L
  • Sterilization Time : 4 - 18 mins
  • Sterilization Temperature : 121 °C / 134 °C
  • No. of Trays : 3
  • Dry Procedure : Vacuum drying

Medical Autoclave LMA-A20

  • Type : B-type; Table-top
  • Capacity : 23 L
  • Sterilization temperature : 134°C
  • Sterilization time : 0 to 90 min
  • Pressure : 0.22 MPa
Medical Autoclave LMA-C10
  • Capacity : 14 L
  • Sterilization Time : 4 - 20 mins
  • Sterilization Temperature : 121 °C / 134 °C
  • No. of Trays : 2
  • Chamber Dimension ( Φ × D ) : 250 × 280 mm
Medical Autoclave LMA-C11
  • Capacity : 17L
  • Sterilization Time : 4 - 20 mins
  • Sterilization Temperature : 121 °C / 134 °C
  • No. of Trays : 2
  • Chamber Dimension ( Φ × D ) : 250 × 350 mm

Plasma Autoclave LPA-A10

  • Capacity : 80 L
  • Door type : Rectangular, single door
  • Chamber material : Anti rust aluminum alloy
  • Power supply : 3 kW / 220 V, Single phase
  • Sterilizing agent : 60 % H<sub>2</sub>O<sub>2</sub>

Plasma Autoclave LPA-A11

  • Capacity : 120 L
  • Door type : Rectangular, single door
  • Chamber material : Anti rust aluminum alloy
  • Power supply : 3 kW / 220 V, Single phase
  • Sterilizing agent : 60 % H<sub>2</sub>O<sub>2</sub>
Plasma Autoclave LPA-A12
  • Capacity : 240 L
  • Door type : Rectangular, double door
  • Chamber material : Anti rust aluminum alloy
  • Power supply : 3 kW / 220 V, Single phase
  • Sterilizing agent : 60 % H<sub>2</sub>O<sub>2</sub>
Plasma autoclave LPA-B10
  • Chamber Volume : 100 L
  • Sterilization temperature : 50 ± 5°C
  • Working pressure : -50 Pa
  • Sterilizing agent : 60 % (H2O2) hydrogen peroxide
  • Sterilizing time : 45 to 50 min

Plasma autoclave LPA-B11

  • Chamber Volume : 130 L
  • Sterilization temperature : 50 ± 5°C
  • Working pressure : -50 Pa
  • Sterilizing agent : 60 % (H2O2) hydrogen peroxide
  • Sterilizing time : 45 to 50 min

Plasma autoclave LPA-B12

  • Chamber Volume : 220 L
  • Sterilization temperature : 50 ± 5°C
  • Working pressure : -50 Pa
  • Sterilizing agent : 60 % (H2O2) hydrogen peroxide
  • Sterilizing time : 45 to 50 min
Portable Autoclave LPOA-A11
  • Volume of Chamber : 18 L
  • Working temperature : 126 ℃
  • Heating mode : Electrically / LPG heated
  • Working pressure : 0.14 ~ 0.16 MPa
  • Max safety pressure : 0.165 MPa
Portable Autoclave LPOA-A12
  • Volume of Chamber : 24 L
  • Working temperature : 126 ℃
  • Heating mode : Electrically / LPG heated
  • Working pressure : 0.14 ~ 0.16 MPa
  • Max safety pressure : 0.165 MPa

Portable Autoclave LPOA-A13

  • Volume of Chamber : 18 L
  • Working temperature : 126 ℃
  • Heating mode : Electrically heated
  • Working pressure : 0.14 ~ 0.16 MPa
  • Max safety pressure : 0.165 MPa

Portable Autoclave LPOA-A14

  • Volume of Chamber : 24 L
  • Working temperature : 126 ℃
  • Heating mode : Electrically heated
  • Working pressure : 0.14 ~ 0.16 MPa
  • Max safety pressure : 0.165 MPa
Portable Autoclave LPOA-A15
  • Volume of Chamber : 18 L
  • Working temperature : 126 ℃
  • Heating mode : Electrically heated
  • Timer range : 0 ~ 60 min
  • Working pressure : 0.14 ~ 0.16 MPa
Portable Autoclave LPOA-A16
  • Volume of Chamber : 24 L
  • Working temperature : 126 ℃
  • Heating mode : Electrically heated
  • Timer range : 0 ~ 60 min
  • Working pressure : 0.14 ~ 0.16 MPa

Ethylene Oxide Sterilizer LEOS-A10

  • Type : Vertical; constant temperature heating box type
  • Door opening : Manual
  • Capacity : 80 L
  • Sterilization temperature : 50℃ ± 3℃
  • Work pressure : -60 kPa

Ethylene Oxide Sterilizer LEOS-A11

  • Type : Vertical; constant temperature heating box type
  • Door opening : Manual
  • Capacity : 120 L
  • Sterilization temperature : 50℃ ± 3℃
  • Work pressure : -60 kPa
Ethylene Oxide Sterilizer LEOS-A12
  • Type : Vertical; constant temperature heating box type
  • Door opening : Manual
  • Capacity : 220 L
  • Sterilization temperature : 50℃ ± 3℃
  • Work pressure : -60 kPa
Ethylene Oxide Sterilizer LEOS-A13
  • Type : Vertical; constant temperature heating box type
  • Door opening : Manual
  • Capacity : 360 L
  • Sterilization temperature : 50℃ ± 3℃
  • Work pressure : -60 kPa

Ethylene Oxide Sterilizer LEOS-A14

  • Type : Vertical; constant temperature heating box type
  • Door opening : Manual
  • Capacity : 460 L
  • Sterilization temperature : 50℃ ± 3℃
  • Work pressure : -60 kPa