Petroleum Testing

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type : Isoperibol
  • Temperature range : 5 to 40°C
  • Measurement range : 5 to 40 MJ/ kg
  • Operation Mode : The outer barrel temperature is constant
  • Temperature resolution : 0.0001°C

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type : Isoperibol
  • Temperature range : 5 to 40°C
  • Measurement range : 5 to 40 MJ/ kg
  • Operation Mode : A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode
  • Temperature resolution : 0.0001°C
Automatic Bomb Calorimeter LABC-B10
  • Calorimeter type : Isoperibol
  • Oxygen filling : Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume : 250 ml
  • Analysis time : < 8 min full test process: <10 min
  • Bomb washing : Manual
Automatic Bomb Calorimeter LABC-B11
  • Calorimeter type : Isoperibol
  • Oxygen filling : Semi-automatic
  • Bomb volume : 282 ml
  • Analysis time : 15 to 25 min
  • Bomb washing : Manual

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline : 86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor Vehicles : National standard: 65.0 to 110.0/RON<br/> National-V standard: 70 to 115.0/RON<br/> Blended gasoline: 75.0 to 120.0/RON<br/> Light gasoline: 50.0 to 85.0 /MON<br/> Isomerized gasoline: 85.0 to 120.0/RON<br/> Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For Ethanol : E93: 92.0 to 95.0/RON<br/> E97: 95.0 to 99.0/RON<br/> Judgement: 60.0 to 120.0/RON
  • Measuring Range For Automobile Diesel Fuels : Cetane number: 25 to 75/CN<br/> Cetane index: 20 to 80/CI
  • Measuring Accuracy : Aviation gasoline: ≤ ± 1.5/MON<br/> Gasoline for motor vehicles: ≤ ± 1.5/RON, ≤ ± 1.5/MO<br/> Automobile diesel fuels: ≤ ± 2.6/CN, ≤ ± 2.6/CI<br/> Regression sample retest: ≤ ± 0.5/RON, ≤ ± 0.5/MON<br/> Regression sample measurement: ≤ ± 1.5/RON, ≤ ± 1.5/MON<br/> Calibration accuracy: ≤ ± 0.2/RON, ≤ ± 0.2/MON

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item : motor gasoline and diesel
  • measurement unit of octane is ON : 40 to 120
  • Permissible error of octane : ± 0.5 max
  • Fluctuate range of octane : ± 0.2 max
  • measurement unit of cetane is CN : 20 to 100
Acid Number and Acidity Tester LAAT-A11
  • Ambient temperature : ≤ 35 °C
  • Relative humidity : ≤ 85 %
  • Precision of titration tube : Scale division is 0.02 ml
  • Total power consumption : ≤ 1200 W
  • Power supply : AC 220 V ± 10 %, 50 Hz
Acid Number Tester LAAT-A12
  • Measurement range : ≥0.05 mg KOH/g
  • Potential measurement range : 0 to 1800.0 mV
  • Burette volume : 10 mL
  • Minimum titration volume : 0.001 ml
  • Burette precision : ±0.1 %FS

Base Number Tester LAAT-A13

  • Volumetric analysis : Titration condensation: 0.1 N;<br> Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration : Titration condensation: 0.1 N;<br> Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control : Titration condensation: 0.1 N;<br> Controlling accuracy: ≤ 10 mV
  • Ambient temperature : 0 ~ 35 ℃
  • Relative humidity : ≤ 85 %

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask : 100 ml,50 ml
  • Conical flask : 100ml
  • Separatory funnel : 250ml
  • Ambient temperature : (-10 )°C to 35 °C
  • Relative humidity : ≤ 85 %
Aniline Point Tester LAPT-A10
  • Measurement range : Room temperature ~ 150°C
  • Stirring speed : 0 ~ 1200 r / min
  • Heating power : 25 W
  • Interior Dimension : 360 × 250 × 545 mm
  • Exterior Dimension : 370 × 320 × 630 mm
Aniline Point Tester LAPT-A11
  • Temperature controlling accuracy : ≤ 0.5 ℃
  • Temperature controlling range : Room temperature ~ 200 ℃
  • Power supply for illumination : 5 V
  • Power of motor : 2 kW

Automatic PMCC Flash Point Tester LCFP-A11

  • Ambient temperature : 10 °C ~ 40 °C
  • Relative humidity : ≤ 80 %
  • Measurement Range : Ambient Temperature ~ 250 °C
  • Flash Point : Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C
  • Resolution : 0.1 °C

Automatic PMCC Flash Point Tester LCFP-A13

  • Ambient temperature : 10 °C ~ 40 ℃
  • Relative humidity : ≤ 80 %
  • Ignition Mode : electron igniter / gas flame
  • Temperature range : Room Temperature ~ 300 ℃
  • Measurement Range : Room Temperature ~ 300 ℃
PMCC Flash Point Tester LCFP-A10
  • Ambient temperature : ≤ 35 °C
  • Relative humidity : ≤ 85 %
  • Temperature range : 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C
  • Aperture of ignition device : 0.8 mm
  • Standard oil cup-Inner diameter : 50.7 ~ 50.8 mm
Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10
  • Ambient temperature : Room temperature to 35 °C
  • Relative humidity : ≤ 85 %
  • Timing range : 1 s to 9 min 59 s
  • Temperature controlling range : Room temperature to 99.9 °C
  • Temperature controlling accuracy : ± 1 °C

Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11

  • Ambient temperature : Room temperature to 35 °C
  • Relative humidity : ≤ 85 %
  • Temperature controlling range : Room temperature to 99.9 °C
  • Temperature controlling accuracy : ± 1 °C
  • Stirring speed : 1500 ± 15 rpm

Density Tester LDMT-A10

  • Cubage of bath : Ф300 × 380 mm
  • Temperature controlling range : 0 °C ~ 100 °C
  • Temperature controlling accuracy : ± 0.2 °C
  • Temperature sensor : Industrial platinum resistance, Pt100
  • Thermometer : Total immersion mercury thermometer
Automatic Distillation Apparatus LADA-A10
  • Heating power : 2 kW
  • Cooling power : 0.5 kW
  • Steam temperature : 0 to 400℃
  • Oven temperature : 0 to 500℃
  • Refrigeration temperature : 0 to 60℃
Benzene Distillation Tester (Low Temperature) LDT-A11
  • Ambient temperature : -10°C to 35°C
  • Relative humidity : ≤ 85 %
  • Thermometer : Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
  • Scale division : 0.1 ℃
  • Total length : 8000 mm

Distillation Tester (low temperature Double units) LDT-A16

  • Graduated flasks : 100 ml
  • Distillation flask : 125 ml
  • Ambient temperature : ≤ 35 °C
  • Relative humidity : ≤ 85 %
  • Temperature controlling accuracy : ± 0.5 °C

Distillation Tester (low temperature single unit) LDT-A17

  • Graduated flasks : 100 ml
  • Distillation flask : 125 mL
  • Ambient temperature : ≤ 30 °C
  • Relative humidity : ≤ 85 %
  • Temperature controlling range : 0 °C to 60 °C
Distillation Tester Dual Units LDT-A15
  • Graduated flasks : 100 ml
  • Scale division of graduated flask : 1ml
  • Distillation flask : 125 ml
  • Ambient temperature : ≤ 35 °C
  • Relative humidity : ≤ 85 %
Distillation Tester Front Type LDT-A14
  • Distillation flask : 125 mL
  • Ambient temperature : Room temperature to 35 °C
  • Relative humidity : ≤ 85 %
  • Thermometer : (-2 )°C to 300 ℃ and (-2) °C to 400 ℃
  • Division value : 1℃

Dropping Point Tester (Air bath) LDPT-A11

  • Ambient temperature : ≤ 35 ℃
  • Relative humidity : ≤ 85 %
  • Heating power of electric furnace : 250 W × 2
  • Total power consumption : ≤ 700 W
  • Power supply : AC 220 V ± 10 %, 50 Hz

Dropping Point Tester (Oil Bath) LDPT-A10

  • Beaker quantity : 600 ml
  • Ambient temperature : (-10) °C ~ 40 °C
  • Relative humidity : ≤ 85 %
  • Thermometer Measurement range : (-5) °C ~ 300 °C
  • Thermometer Scale division : 1 °C
Engler Viscometer LEV-A10
  • Graduated Flask : 200 ± 0.2 ml
  • Standard Water Value : 51 ± 1 s
  • Temperature Range : 0 ~ 100 °C
  • Temperature Controlling Accuracy : ± 0.2 °C
  • Accuracy Of Timer : 0.01 s
Engler Viscometer LEV-A11
  • Graduated Flask : 100 ml
  • Standard Water Value : 51 ± 1 s
  • Temperature Range : 0 ~ 100 °C
  • Temperature Controlling Accuracy : ± 0.1 °C
  • Accuracy Of Timer : 0.01 s

Engler Viscometer LEV-B10

  • Graduated Flask : 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
  • Standard Water Value : 51 ± 1 s
  • Temperature Range : 0 ~ 100 °C
  • Ambient Temperature : 10 °C ~ 40 °C
  • Temperature Controlling Accuracy : ± 0.1 °C

Existent Gum Tester LEGT- B30

  • Bath type : Oil bath
  • Bath capacity : 5000 ml ± 50 ml
  • Ambient temperature : Room temperature to 35 °C
  • Relative humidity : ≤ 85 %
  • Temperature controlling range : RT to 250 °C
Existent Gum Tester LEGT- B31
  • Evaporation bath type and size : Aluminum block bath, φ260 × 130 mm
  • Holes for testing : 3 pieces
  • Size of holes for testing cylinder : φ51 × 70 mm
  • Flow rate display : Flow meter
  • Working temperature : 60 ℃ to 165 ℃
Existent Gum Tester LEGT- B32
  • Evaporation bath type and size : Aluminum bath φ260 × 130 mm
  • Holes for testing : 5 pieces
  • Size of holes for testing cylinder : φ51 × 70 mm
  • Working temperature : 160 ℃ ~ 165℃
  • Working pressure for decompression valve : 0.07 MPa

Kinematics Viscometer LKV-A10

  • Ambient temperature : 15 to 35°C
  • Relative humidity : ≤ 85%
  • Capillary viscometer : 6 capillary Pinkevitch viscometer tubes
  • Stirring motor : 1200 rpm
  • Temperature range : Ambient to 100°C

Kinematics Viscometer LKV-A11

  • Ambient temperature : (-10) °C ~ 35 °C
  • Relative humidity : ≤ 85 %
  • Capillary viscometer : 11 pieces
  • Stirring motor : 6 W, 1200 rpm
  • Temperature controlling accuracy : ± 0.1 °C
Kinematics Viscometer LKV-A12
  • Ambient temperature : (-10) °C ~ 35 °C
  • Relative humidity : ≤ 85 %
  • Capillary viscometer : 11 pieces
  • Stirring motor : 6 W, 1200 rpm
  • Temperature controlling range : Ambient temperature ~ 100 °C
Kinematics Viscometer LKV-A13
  • Ambient temperature : (-10) °C ~ 35 °C
  • Relative humidity : ≤ 85 %
  • Capillary viscometer : 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group
  • Stirring motor : 6 W, 1200 rpm
  • Sample quantity : 3 piece at the same time

Kinematics Viscometer LKV-A15

  • Ambient temperature : (-10) °C ~ 35 °C
  • Relative humidity : ≤ 85 %
  • Capillary viscometer : 11 pieces
  • Stirring motor : 6 W, 1200 rpm
  • Sample quantity : 4 piece at the same time

Kinematics Viscometer LKV-A16

  • Ambient temperature : 0 ~ 40 ºC
  • Relative humidity : 20 ~ 90 %, RH while 40 ℃
  • Temperature controlling accuracy : ± 0.1 °C
  • Timing range : 0.0 s ~ 9999.9 s
  • Barometric : 96 ~ 103 kPa
Automatic Pour Point Tester LLTT-A23
  • Ambient temperature : ≤ 30 ℃
  • Refrigeration speed : > 40 °C / 10 min
  • Repeatability for solidifying point : ≤ 2 °C
  • Repeatability for pour point : ≤ 3 °C
  • Reproducibility : ± 4 °C
Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12
  • Ambient temperature : (-10)℃ ~ 35 ℃
  • Relative humidity : ≤ 85 %
  • Sample cup Inner diameter : 31.0 ~ 32.0 mm
  • Sample cup Wall thickness : 1.0 ~ 1.5 mm
  • Sample cup Height : 115 ~ 125 mm

Freezing Point Tester LLTT-A11

  • Freezing point range : -54°C to 2°C
  • Cold bath measurement temperature range : -70° to 20°C
  • Temperature controlling accuracy : ±0.5°C
  • Bath liquids stirring : Electric
  • Bath liquids stirring range : 1200 r/min

Multifunctional Low Temperature Tester LLTT-A16

  • Refrigeration system : New-type refrigeration compressor
  • Controlling temperature of cold trough : Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C
  • Ambient temperature : ≤ 30 ℃
  • Relative humidity : ≤ 85 %
  • Dimensions : 930 x 570 x 108 mm
Pour and Cloud Point Tester LLTT-A14
  • Chamber quantity : 2 chambers
  • Chamber 01 temperature control : Ambient to -51 ℃
  • Chamber 02 temperature control : Ambient to -65 ℃
  • Temperature precision : ±1°C
  • Ambient temperature : ≤ 30°C
Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15
  • Refrigeration system : New-type refrigeration compressor
  • Controlling temperature of cold trough : Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
  • Ambient temperature : ≤ 30 ℃
  • Relative humidity : ≤ 85 %
  • Inner Dimensions : 560 x 380 x 250 mm

Automatic Cleveland Open Cup Flash Point Tester LOFP-A12

  • Ambient Temperature : 10 ℃ ~ 40 °C
  • Relative Humidity : ≤ 80 %
  • Temperature Measurement- Full Scale : Ambient temperature to 300 °C
  • Temperature Measurement- Repeatability : ≤ 8 °C
  • Temperature Measurement- Reproducibility : ≤ 16 °C

Automatic COC Flash & Fire Point Tester LOFP-B10

  • Ambient Temperature : 10 ℃ ~ 40 ℃
  • Relative Humidity : ≤ 85 %
  • Temperature Measurement- Full Scale : Ambient temperature to ~ 400 ℃
  • Temperature Measurement- Repeatability : ≤ 4 ℃
  • Test accuracy : 0.005
Cleveland Open Cup Flash Point Tester LOFP-A11
  • Thermometer : 6 ℃ ~ 400 ℃
  • Scale Division : 2 °C
  • Spout Aperture : 0.6 ~ 0.8 mm
  • Ambient Temperature : -10 ℃ ~ 50 ℃
  • Relative Humidity : ≤ 85 %
Open Cup Flash Point Tester LOFP-A10
  • Thermometer : 0 ℃ ~ 360 °C
  • Scale Division : 1 °C
  • Ambient Temperature : ≤ 35 °C
  • Relative Humidity : ≤ 85 %
  • Outer Crucible-Material : Carbon structural steel

Color Tester LCT-A20

  • Light source : 220 V, 100 W
  • Temperature of grinding milk white light bulb : 2750 ± 50 K
  • Light hole( Φ14) : 26 pieces
  • Color comparing tube : Φ32 mm
  • Dimension : 440 x 420 x 340 mm

Insulating Oil Breakdown Voltage Tester LIBT-A23

  • Power supply : AC 220 V ± 5 % , 50Hz
  • Measurement range : 0 ~ 75 kV
  • Voltage rising rate : 3 kV ± 10 % / s
  • Distance between electrodes : 2.5 mm
  • Output power : 2 kVA
Mechanical Impurity Tester (Weight Method) LMIT-A21
  • Dimension : 390 x 260 x 590 mm
  • Total power consumption : ≤ 1200 W
  • Power supply : AC 220 V ± 10 %, 50 Hz
  • Heating power of water bath : 1000 W
  • Relative humidity : ≤ 85 %
Wax Oil Content Tester LWCT-A22
  • Power supply : AC 220 V ± 10 %, 50 Hz
  • Temperature controlling range in water bath : RT ~ 90 ℃ ± 5 ℃
  • Cooling bath temperature : (-35) ℃ ± 1 ℃
  • Evaporation temperature : 35 ℃ ± 1 ℃
  • Flow rate : 2 ~ 3 L / min

Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

  • Samples : 2
  • Oil bath cubage : 30 L
  • Angle between bomb and water surface : 30 °
  • Speed of rotary assembly : 100 ± 5 RPM
  • Pressure sensor : 0 to 1.6 Mpa; Accuracy: ±2%

Distillate Fuel Oil Oxidation Stability Tester LOST-D12

  • Samples : 8
  • Temperature : 100 ℃
  • Temperature controlling accuracy : 0.1 ℃
  • Flow meter : 3 ± 0.3 L / H oxygen
  • Power supply : 220 V ± 10 %, 60 Hz
Gasoline Oxidation Stability Tester LOST-D13
  • Type : Compact; Desktop
  • Design : Integrated
  • Bath : Metal bath (without water usage)
  • Temperature control point of metal bath : 100℃ ± 1℃
  • Ambient temperature : ≤ 30℃
Oxidation Stability Tester (Lubricating Grease) LOST-D20
  • Temperature Range : Ambient to 150℃
  • Temperature Precision : ± 0.1°C
  • Test Unit : 2 units
  • Heating Power : 1800 W
  • Ambient Temperature : (Room temperature to 35°C

Transformer Oil Oxidation Stability Tester LOST-D11

  • Samples : 6
  • Temperature controlling mode : Automatic digital temperature
  • Temperature controlling range : Room temperature ~ 160 °C
  • Temperature controlling accuracy : ± 0.2 °C
  • Power supply : 220 V, 50 Hz

Oxygen Bomb Calorimeter LBC-C20

  • Heat capacity : 14000 ~ 15000 J / K
  • Temperature measurement range : 10 ~ 35 ℃
  • Repeatability error : ≤ 0.2 % (Grade C)
  • Endured pressure in oxygen bomb : 20 MPa
  • Operation environment temperature : 15 ~ 28 ℃
Oxygen Bomb Calorimeter LBC-C21
  • Temperature controlling range : 10 ℃ ~ 35 ℃
  • Temperature resolution : 0.001 ℃
  • Mean value of heat capacity : 15 kJ / K
  • Ambient temperature : 20 ℃ ± 5 ℃
  • Relative humidity : ≤ 85 %
Oxygen Bomb Calorimeter LBC-C22
  • Temperature measurement range : 10 ~ 35 ℃
  • Repeatability error : ≤ 0.2 % (Grade C)
  • Endured pressure in oxygen bomb : 20 MPa
  • Operation environment temperature : 15 ~ 28 ℃
  • Temperature resolution : 0.001 ℃

Carbon Residue Tester (CONRADSON METHODS) LRCT-B10

  • Porcelain crucible : 30 ml
  • Inner iron crucible : 75 ml
  • Outer iron crucible : 190 ml
  • Burner : Mig Burner
  • Dimensions : 400 x 380 x 270 mm

Carbon Residue Tester (Digital Temperature Controlled Electric Furnace Methods) LRCT-B11

  • Bath type : Four holes with a furnace
  • Heating type : Electric resistance furnace
  • Temperature controlling range : 0 ~ 520 °C
  • Temperature controlling accuracy : ± 5 °C
  • Relative humidity : ≤ 85 %
Carbon Residue Tester (Ramsbottom) LRCT-B20
  • Coking furnace : Metal furnace
  • Heating mode : Electric heating
  • Test unit : 5 units
  • Temperature range : Ambient to 550°C
  • Temperature precision : ≤ ± 5℃
Rotational Viscometer LRV-A10
  • Viscosity measurement range : 10 ~ 2000000 MPa•s
  • Ambient temperature : 5 °C ~ 35 °C
  • Ambient humidity : Not more than 80 %
  • Spindles : Four spindles of No.1 ~ 4
  • Spindle speed : 0.3, 0.6, 1.5, 3, 6, 12, 30 and 60 rpm

Copper Strip Corrosion Tester LRCT-A13

  • Sample hole : 4 pieces
  • Sample quantity : 4 to 12 pieces
  • Ambient temperature : Room temperature to 35 °C
  • Temperature controlling range : Room temperature to 100°C
  • Temperature controlling accuracy : ± 1°C

Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10

  • Sample hole : 2 pieces
  • Speed of stirring motor : 1400 rpm
  • Ambient temperature : 10 to 35°C
  • Temperature controlling range : Room Temperature to 100°C
  • Temperature controlling accuracy : ± 0.5°C
Lubricating Oil Rust Characteristics Tester LRCT-A11
  • Sample hole : 4 pieces
  • Speed of stirring motor : 1400 rpm
  • Speed for sample stirring : 1000 ± 50 rpm
  • Ambient temperature : Room temperature to 35°C
  • Temperature controlling range : 0 to 100°C
Rust Characteristics and Corrosion Tester LRCT-A12
  • Sample hole : 4 pieces
  • Ambient temperature : Room temperature to 35°C
  • Temperature controlling range : 0 to 100°C
  • Temperature controlling accuracy : ± 1°C
  • Relative humidity : ≤ 85 %

Dark Petroleum Products Sulphur Content Tester (Tubular Oven Method) LST-A11

  • Air flow rate : Not less than 150 L / h
  • Max. Preset time : 99 min 59 s (100 min)
  • Chamber diameter of oven : Φ22 mm
  • Heating power of oven : 1400 W × 2
  • Max. Temperature of oven : 950 °C

X-ray Fluorescence Sulfur in Oil Analyzer LST-A10

  • Sample quantity : 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)
  • Measurement time : 60, 120, 240, 300, and 600 s at random
  • Measurement range : 7 ppm to 5 %
  • Repeatability : < 0.029 (S + 0.6)
  • Reproducibility : < 0.063 (S + 0.6)
Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11
  • Test bomb : Two samples or a group of parallel samples
  • Bath temperature : 37.8 °C
  • Temperature controlling accuracy : 0.1 °C
  • Dimensions : 500 × 560 × 680 mm, 950 × 540 × 720 mm
  • Heating power of water bath : 1400 W
Vapor Pressure Tester (REID METHOD) LVPT-C10
  • Operation temperature of water bath : RT ~ 90 °C
  • Temperature controlling accuracy : ± 0.1 °C
  • Dimensions : 550 × 520 × 102 mm
  • Pressure meter accuracy : ± 0.4 % kPa
  • Heating power of water bath : 1600 W

Coulometric Karl Fischer Titrator LWT-A30

  • Ambient Temperature : 10°C to 35°C
  • Measurement Range : 0 to 100 mg
  • Resolution : 0.1 µg
  • Max. Electrolysis Speed : 40 µg /s
  • Amount and Precision of electrolysed water : 10 µg to 1000 µg, ± 2 µg and >1000 µg, 0.2 %

Coulometric Karl Fischer Titrator LWT-A31

  • Maximum current : 400 mA
  • Measurement range : 3 µg to 9999.9 µg
  • Resolution : 0.1 µg
  • Precision 1 : ± 2 µg (3µg H<sub>2</sub>O to 20µg H<sub>2</sub>O)
  • Precision 2 : ± 3 µg (20µg H<sub>2</sub>O to 100µg H<sub>2</sub>O)
Crude Petroleum Water Content Tester LWT-B10
  • Ambient Temperature Range : -10 to 35°C
  • Relative Humidity : ≤85%
  • Distillation Flask : 1000 ml
  • Receiver : 5 ml, with 0.05 ml graduation
  • Condenser : 400 mm with ± 5 mm accuracy
Water Content Tester LWT-A10
  • Ambient Temperature Range : ≤ 35°C
  • Relative Humidity : ≤ 85%
  • Heating Mantle Cap Power : 1000 W
  • Sample Determination : 1 at a time
  • Dimension : 580 × 350 × 300 mm

Water Content Tester LWT-A11

  • Ambient Temperature Range : ≤ 35°C
  • Relative Humidity : ≤ 85%
  • Heating Mantle Cap Power : 1000 W × 2
  • Sample Determination : 2 at a time
  • Dimension : 690 × 570 × 310 mm

Automatic Tag Closed Flash Point Tester LACF-A10

  • Experimental temperature range : -50 to 70°C
  • Test sample volume : 50 ml
  • Ambient temperature range : 10 to 40°C
  • Humidity : ≤ 85%
  • Ignition gas source : Pipelined gas or LPG
Specific Gravity Tester LSGT-A10
  • Vessel Volume :  4000 ml × 2
  • Power of Vacuum pump : 160 W
  • Negative power : 3.7 kPa(27.75 mmHg)
  • Power of shaking machine : 30 W
  • Power supply : AC(220±10%)V, 50Hz
Automatic Dielectric Tester LADT-A10
  • Capacity : 2.0 kVA
  • Speed of voltage increase : 2 k V/ s
  • Voltage inspection accuracy : 0.01
  • Breakdown sensitivity : < 0.1 kV
  • Waveform distortion : ≤ 1 %

Automatic Softening Point Tester LSPT-A10

  • Measurement range : 32 ℃ to 160 ℃
  • Ambient temperature : 35 °C
  • Temperature resolution : 0.01 ℃
  • Beaker volume : 1000 mL
  • Relative humidity : ≤85%

Automatic Thermogravimetric Analyzer LTGA-A10

  •  Temperature range : Room temperature to 1000 ºC
  • Temperature resolution : 0.1 ºC
  • Temperature fluctuation : ±0.1 ºC
  • Heating rate : 1 ~ 80 ºC / min
  • Cooling time : 15min  (1000ºC ~ 100ºC)
Penetrometer LMPT-A10
  • Measurement range : 0 to 600 penetration scale
  • Timing controller : 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec
  • Time accuracy : ± 0.1 seconds
  • Resolution : 0.01 mm
  • Penetration accuracy : ± 1 penetration
Penetrometer LMPT-A11
  • Measurement range : 0 to 600 penetration scale
  • Timing controller : 5 sec or 60 sec
  • Time accuracy : ± 0.1 seconds
  • Resolution : 0.01 mm
  • Penetration accuracy : ± 1 penetration

Penetrometer LMPT-A12

  • Penetrometer : <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Measurement range</strong></td><td>0 to 600 penetration scale</td></tr><tr><td><strong>Timing controller</strong></td><td>5 sec or 60 sec</td></tr><tr><td><strong>Time accuracy</strong></td><td>± 0.1 seconds</td></tr><tr><td><strong>Resolution</strong></td><td>0.1 penetration</td></tr><tr><td><strong>Penetration accuracy</strong></td><td>± 1 penetration</td></tr><tr><td><strong>Weight of standard needle</strong></td><td>2.5 ± 0.05 g</td></tr><tr><td><strong>Dimensions (W × L × H)</strong></td><td>700 × 400 × 750 mm</td></tr><tr><td><strong>Weight</strong></td><td>30 kg</td></tr></table>
  • Circulatory Water Bath : <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Bath volume</strong></td><td>3.5 L</td></tr><tr><td><strong>Temperature range</strong></td><td>5 °C to 60 °C</td></tr><tr><td><strong>Temperature accuracy</strong></td><td>± 0.1 °C</td></tr><tr><td><strong>Circulatory water quantity</strong></td><td>3 L/minute</td></tr><tr><td><strong>Pump Lift</strong></td><td>2 m</td></tr><tr><td><strong>Power consumption</strong></td><td>1200 W</td></tr><tr><td><strong>Power supply</strong></td><td>AC 220V ± 10 %, 50 Hz</td></tr><tr><td><strong>Dimensions (W × L × H)</strong></td><td>600 × 400 × 650 mm</td></tr><tr><td><strong>Weight</strong></td><td>40 kg</td></tr></table>

Penetrometer LMPT-A13

  • Measurement range : 0 to 600 penetration scale
  • Timing range : 0 sec to 60 sec
  • Time accuracy error : ≥ ± 0.1 seconds
  • Resolution : 0.1 penetration
  • Power consumption : 200 W
Foaming Characteristics Tester LFCT-A10
  • Temperature Range : Ambient to 100°C
  • Temperature Precision : ± 0.1°C
  • Air Flow : 94 mL ± 5 mL/min, with flowmeters
  • Timing Unit : 0 to 99 min 59 s, resolution 1 s
  • Control System : Single chip microcontroller
Ash Content Tester LACT-A10
  • Electric Muffle Furnace : <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Controlled temperature</strong></td><td>775 ±25 ℃</td></tr><tr><td><strong>Temperature rising time of empty chamber</strong></td><td>≤ 50 min</td></tr><tr><td><strong>Furnace temperature uniformity</strong></td><td>≤ 15℃</td></tr><tr><td><strong>Internal dimension</strong></td><td>200 × 120 × 80 mm</td></tr><tr><td><strong>External dimension</strong></td><td>490 × 490 × 450 mm</td></tr><tr><td><strong>Power consumption</strong></td><td>2.5 kW</td></tr><tr><td><strong>Power supply</strong></td><td>AC 220V ±10%, 50 Hz</td></tr><tr><td><strong>Net weight</strong></td><td>35 kg</td></tr></table>
  • Temperature controller : <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Maximum control temperature</strong></td><td>1200 ℃</td></tr><tr><td><strong>Dimension</strong></td><td>500 × 300 × 235 mm</td></tr><tr><td><strong>Power consumption</strong></td><td>5000 W</td></tr><tr><td><strong>Power supply</strong></td><td>AC 220±10% V, 50Hz</td></tr><tr><td><strong>Net weight</strong></td><td>5 kg</td></tr></table>
  • Electric heating plate : <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Heating power</strong></td><td>(1 to 6) grades, continuously adjustable</td></tr><tr><td><strong>Temperature</strong></td><td>400℃</td></tr><tr><td><strong>Diameter of heating plate</strong></td><td>Φ 180 mm</td></tr><tr><td><strong>Dimension</strong></td><td>280 × 250 × 90 mm</td></tr><tr><td><strong>Power consumption</strong></td><td>2000 W</td></tr><tr><td><strong>Power supply</strong></td><td>AC 220±10%V, 50Hz</td></tr></table>

Mercaptan Sulfur Tester LMST-A10

  • Potential measuring range : (0 to ±1999.5) Mv
  • Intrinsic error : 0.1 % ±0.5 mV
  • Input impedance : Ri ≥1 × 1012 Ω
  • Burette capacity : 10 mL
  • Burette accuracy :  ±0.1 % (F•S)

Constant Temperature Needle Penetration Tester LTNP-A10

  • Measuring range : 0 to 700 taper degree (digital display table 0-70 mm)
  • Timing device : Timing error is less than ±0.1 s
  •  Resolution : 0.01 mm
  • Needle insertion accuracy : ±1 cone insertion degree
  • Temperature range : 10 to 50˚C