Automatic horizontal tensile tester TP-B11

  • Sample (size) length : 90 to 200 mm
  • Sample width : 15 mm, 25 mm, 50mm
  • Measuring range : 0 to 30, 0 to 100 N,0 to 300 N
  • Accuracy : ± 1 %
  • Tensile strength velocity : 1 to 399 mm/min (adjustable)

Automatic horizontal tensile tester TP-B12

  • Sample (size) length : 180 mm (180, 150, 100, 90, 50 mm adjustable)
  • Sample width : 15 mm
  • Measuring range : 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
  • Accuracy : ± 1 %
  • Tensile strength velocity : 1 to 399 mm/min (adjustable)
Bekk Smoothness tester TP-L20
  • Measuring scope : ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)
  • Accuracy : ±0.1 s within 300 s
  • Vacuum system volume (ml) : Bigger volume: 380 ± 1<br/> Smaller volume: 38 ± 1
  • Contact pressure : 100 ± 2 kPa
  • Vacuum scope : I) 50.66 to 48.00<br/> II) 50.66 to 48.00<br/> III) 50.66 to 29.33<br/> Automatic: No limit
Carton compression tester TP-I10
  • Measuring range : 0.1 to 10 kN
  • Indication error : < ± 1%
  • Platen Size : 500×500 mm (customized)
  • Operating stroke : 500 mm (customized)
  • Compression speed : 10 mm/ min

Carton compression tester TP-I11

  • Measuring range : 1 to 50 kN
  • Indication error : < ± 1%
  • Platen Size : 800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized)
  • Operating stroke : 800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized)
  • Compression speed : 10 mm/ min

COBB sample cutter TP-C30

  • Sample diameter : 125 mm
  • Sample error : ± 0.2 mm
  • Sample Thickness : 0.1 to 1.0 mm
  • Dimension : 240×288×435 mm
  • Net Weight : 25 kg
Aging Oven TAO-A10
  • The maximum temperature : 300°C
  • Temperature fluctuation : Within ± 0.5°C
  • Temperature uniformity : Within ± 1°C
  • Rotate speed of the turntable : 11 r/min to 12r/min, turntable dimension diameter: 285 mm
  • Quantity of heaters : 2 pcs
Charpy/ Izod Impact Tester TCI-A10
  • Impact Speed & Energy (charpy) : 2.9 m/s for 1J, 2J, 4J, 5J & 3.8 m/s for 7.5J, 15J, 25J
  • Impact energy (Izod) : 3.5 m/s for 1J, 2J, 4J, 5J, 7.5J, 15J, 25J
  • Resolution of impact energy : 0.001 J
  • Pendulum up angle : 160°
  • Impact center distance (Charpy) : 221 mm for 1J, 2J, 4J, 5J & 380 mm 7.5J, 15J, 25J

Falling Weight Impact Tester TFWT-A10

  • Temperature range : 10 to 35°C
  • Maximum falling height : 2000 mm
  • Resolution of displacement : 1 mm
  • Height error : < ± 2 mm
  • Hammer mass : 0.25 to 16 kg

Heat sealer THS-A10

  • Seal temperature : Room temperature -250°C
  • Control accuracy : ± 0.2°C
  • Dwell time : 0.1 S to 999.9 S
  • Dwell pressure : 0.05 to 0.7 MPa
  • Heating mode : Single and double heating surface
Lasting adhesive tester TLAT-A10
  • Standard roller : 2000 ± 50 g
  • Testing stations : 3
  • Dimension (L*W*H) tester : 320×210×550 mm (3 stations)
  • Weight for stations : 10 kg (3 stations)
  • Weight of the plates : 1000 ± 3 g ( with triangle hook)
Lasting adhesive tester TLAT-A11
  • Standard roller : 2000 ± 50 g
  • Testing stations : 6
  • Dimension (L*W*H) tester : 650×210×550 mm (6 stations)
  • Weight for stations : 15 kg (6 stations)
  • Weight of the plates : 1000 ± 3 g ( with triangle hook)

DIN abrasion tester TDAT-A10

  • Test arm weight : 2.5 N
  • Additional Loads : 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
  • Idler : 150 mm
  • Abrasion stroke : 40 ± 0.2 M
  • Horizontal displacement : 4.2 mm/ rotation

Mooney viscometer TMV-A10

  • Control temperature range : Normal temperature to 200°C
  • Temperature display resolution : 0.01°C
  • Temperature control accuracy : ± 0.3°
  • Calibration accuracy : Mooney value ± 0.5
  • Rotor speed : 2 rpm
No rotor rheometer TNRR-A10
  • Temperature tester : Room temperature to 200°C
  • Temperature display resolution : 0.1°C
  • Temperature control accuracy : ≤ ± 0.3°C
  • Rotor speed : 100 times/ min
  • Die cavity frequency : 1.7 Hz
Rubber low temperature brittleness tester TRBT-A10
  • Temperature range : -60°C to 0°C
  • Temperature accuracy : ± 0.5°C
  • Impact speed : 2 m/s ± 0.2 m/s
  • Temperature fluctuation : <± 0.5°C
  • Distance between center of impact or bottom of gripper : 11 ± 0.5 mm

Rubber Low Temperature Brittleness Tester TRBT-A11

  • Temperature control range : Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
  • Temperature accuracy : ± 0.3 ℃
  • Impact speed : 0℃ to -30℃ around 2.5 ℃/min </br> -30℃ to -40℃ around 2.5 ℃/min </br> -40℃ to -70℃ around 2.0 ℃/min</br>
  • Max dimension L × W × H : 910 × 510 × 860 mm
  • Effective test space of the chamber L × W × H : 280 × 170 × 120 mm

Rubber-weiss plasticity testing machine TRWM-A10

  • Temperature range : RT 50° to 300°
  • Temperature accuracy : ± 1°
  • Measuring range : 0.01 to 25 mm
  • Accuracy : ± 0.01 mm
  • Load : 49 N ± 0.05 N
Digital Brinell hardness Tester TDBH-A10
  • Test force : 612.5 N, 980 N, 1225 N
  • Brinell hardness test : 1837.5 N, 2450 N, 4900 N/7350 N, 9800 N, 14700 N/29400 N
  • Hardness measuring area : 8 to 650 HBW (hard metals steel ball)
  • Hardness indication : Digital display
  • Ball indenter : 2.5, 5, 10 mm
Digital low load Vickers Hardness tester TDVH-A10
  • Test force : 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N
  • Hardness value symbol : HV1, HV5, HV10, HV20, HV30, HV250
  • Error range in display : ± 3.0 %, ± 2.0 %
  • Hardness indication : Digital display
  • Hardness value range in Measure : 5 HV to 2500 HV

Portable Vibration Calibrator LPVC-A10

  • Frequency (continually adjustable) : 10 Hz to1280 Hz + 0.01 %
  • Amplitude acceleration ( at 30m/s2 pk ) : 40 Hz to 320 Hz + 0.3 dB + 1 digit
  • Amplitude velocity ( at 25mm / sec pk ) : 40 Hz to 320 Hz + 0.5dB +1 digit
  • Amplitude displacement ( at 50 μm pk-pk ) : 40 Hz to 320 Hz + 0.5 dB + 1 digit
  • Probe : 5 mm , 8 mm and 11mm probe

Rockwell hardness meter (motorized type) TRHM-B10

  • Preliminary test force : 98 N
  • Total test force : 588, 980, 1471 N
  • Brinell hardness test : 306, 613, 1839 N
  • Vickers hardness test : 294, 588, 980 N
  • Magnification of Microscope : 37.575 x
Rockwell hardness meter TRHM-A10
  • Preliminary test force : 98 N
  • Total test force : 588, 980, 1471 N
  • Total test force dwell time : 0 to 30 S
  • Hardness indication : Analogue display
  • Resolution : 0.5 HR
Rockwell hardness meter TRHM-A11
  • Preliminary test force : 98 N
  • Total test force : 588, 980, 1471 N
  • Total test force dwell time : 1 to 30 S
  • Hardness indication : Digital display
  • Resolution : 0.1 HR

Benchtop gloss meter TBGM-A10

  • Test angle : 60°
  • Gloss aperture : 2 × 3 mm
  • Measurement range : 0 to 1000 GU
  • Repeatability : 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)
  • Reproducibility : 1.0 GU (0 to 100 GU), 1.0 % GU (100 to 1000 GU)

Soil moisture meter TSMM-A10

  • Measurement range : 0 to 80 %
  • Resolution : 0.1
  • Accuracy : ± 2 % n (non-saturation condition)
  • Needle : 280 mm
  • Display : Digital LCD 1.69×1.04 inches
Soil moisture meter TSMM-A11
  • Measurement range : 0 to 90 %
  • Resolution : 0.1 or 0.01
  • Accuracy : ± 5 % n (non-saturation condition)
  • Needle : 235 mm
  • Display : Digital LCD 1.69×1.04 inches
Soil moisture meter TSMM-A12
  • Measurement range : 0 to 60 %
  • Resolution : 0.1
  • Accuracy : ± 5 % n (non-saturation condition)
  • Needle : 280 mm
  • Display : Digital LCD 1.69×1.04 inches

Soil nutrient tester TSNA-A10

  • Measuring range : 0.001 to 9999
  • Stability : A (absorbency of light) <0.003 within 3 mins
  • Linearity error : <3.0 %
  • Repeatability error : A (absorbency of light) <0.005
  • Wavelength range : Red light: 680 ± 2 nm, Blue light: 420 ± 2 nm, Green light: 510 ± 2 nm, Orange light: 590 ± 2 nm

Soil nutrient tester TSNA-A11

  • Measuring range : 0.001 to 9999
  • Stability : A (absorbency of light) <0.003 within 3 mins
  • Linearity error : <3.0 %
  • Repeatability error : A (absorbency of light) <0.005
  • Wavelength range : Red light: 680 ± 2 nm, Blue light: 420 ± 2 nm, Green light: 510 ± 2 nm
Soil Salinity tester TSST-A10
  • Salinity Measurement range : 0.00 to 19.99 ms/cm
  • Measuring accuracy : EC ± 2% full scale
  • Temperature Measurement range : -5 to 50°C
  • Temperature accuracy : ± 0.5°C
  • Temperature compensation : 0 to 50°C