info@labtron.us
Labtron
Request Quote

Benchtop Conductivity Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop conductivity meter LBCM-A11

  • Conductivity measurement range : 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
  • Conductivity accuracy : ± 1 % F.S.
  • Conductivity resolution : 0.01, 0.1, 1
  • Conductivity calibration solutions : 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm
  • Conductivity calibration points : 1 - 3 points

Benchtop Conductivity Meter LBCM-A13

  • Conductivity measurement range : 0.000 μS/cm to 3000mS/cm
  • Resistivity measurement range : 5.00 Ω·cm to 100.0 MΩ·cm
  • TDS measurement range : 0.000 mg/L to 1000g/L
  • Salinity measurement range : 0.00 to 8.00 %
  • Temperature measurement range : -5.0 to 135.0 °C

Benchtop Conductivity Meter LBCM-A14

  • Conductivity Mode : <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Conductivity measurement range</strong></td><td>0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm</td></tr><tr><td><strong>Conductivity accuracy</strong></td><td>±1% F.S.</td></tr><tr><td><strong>Conductivity resolution</strong></td><td>0.001, 0.01, 0.1, 1</td></tr><tr><td><strong>Conductivity calibration points</strong></td><td>1 to 3 points</td></tr><tr><td><strong>Conductivity calibration solutions</strong></td><td>10 µS/cm , 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm</td></tr></table>
  • TDS Mode : <table class="table table-striped table-bordered table-responsive"><tr><td><strong>TDS measurement Range</strong></td><td>0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)</td></tr><tr><td><strong>TDS Accuracy</strong></td><td>± 1 % F.S.</td></tr><tr><td><strong>TDS Factor</strong></td><td>0.01 to 1.00 (default 0.5)</td></tr><tr><td><strong>TDS Calibration points</strong></td><td>3 points</td></tr></table>
  • Temperature Mode : <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Temperature range</strong></td><td>0 to 105°C, 32 to 221°F</td></tr><tr><td><strong>Temperature accuracy</strong></td><td>±1°C</td></tr><tr><td><strong>Temperature resolution</strong></td><td>0.1°C, 0.1°F</td></tr><tr><td><strong>Temperature calibration points</strong></td><td>1 point</td></tr><tr><td><strong>Temperature Compensation Range and Mode</strong></td><td>Manual or Automatic, 0 to 100°C , 32 to 212°F</td></tr><tr><td><strong>Temperature coefficient</strong></td><td>0.0 to 10.0 % per °C</td></tr></table>
  • Cell constant : K=0.1, 1, 10
  • Power requirements : DC 9 V, using AC adapter, AC 220 V, 50 Hz