Enquiry Form

info@labtron.us

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double Beam UV-Vis Spectrophotometer LUS-B10

  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 1.8 nm
  • Optical System : Double beam
  • Wavelength Accuracy : ±0.3 nm
  • Wavelength Repeatability : ≤0.1 nm

Double Beam UV-Vis Spectrophotometer LUS-B11

  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 1.8 nm
  • Optical system : Double beam; 1200 lines/mm grating
  • Wavelength accuracy : ±0.1nm (D2 656.1nm), ±0.3nm @ all
  • Wavelength repeatability : 0.2 nm

Double Beam UV-Vis Spectrophotometer LUS-B12

  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 1.8 nm
  • Optical System : Double beam, C-T monochromator,1200 L/mm holographic grating
  • Wavelength Accuracy : ±0.3 nm
  • Wavelength Repeatability : 0.2 nm
Double Beam UV-Vis Spectrophotometer LUS-B13
  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 1.0 nm
  • Optical System : Double beam
  • Wavelength Accuracy : ±0.3 nm
  • Wavelength Repeatability : ≤0.1 nm
Double Beam UV-Vis Spectrophotometer LUS-B20
  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 1.0 to 5.0 nm (adjustable)
  • Optical system : Double beam, C-T monochromator, 1600 L/mm holographic grating
  • Wavelength accuracy : ±0.3 nm
  • Wavelength repeatability : 0.1 nm

Double Beam UV-Vis Spectrophotometer LUS-B40

  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 0.5/1/2/4 nm
  • Wavelength Accuracy : ± 0.1nm (D2, 656.1 nm), ± 0.3 nm full range
  • Wavelength Repeatability : ≤ 0.1 nm
  • Optical system : Double beam grating 1200 lines/mm

Double beam UV-Visible Spectrophotometer LUS-B15

  • Wavelength range : 190 ~ 1100 nm
  • Spectral bandwidth : 2 nm
  • Wavelength accuracy : 0.5 nm
  • Wavelength repeatability : ≤ 0.2 nm
  • Transmittance accuracy : ≤ 0.05 % T

Double Beam UV/Vis Spectrophotometer LUS-B16

  • Wavelength Range : 190 ~ 1100 nm
  • Setting Wavelength : Automatic
  • Spectral Bandwidth : 0.5 / 1.0 / 2.0 / 4.0 nm adjustable
  • Wavelength Accuracy : ± 0.3 nm
  • Wavelength Repeatability : ≤ 0.1 nm
Double Beam UV/Vis Spectrophotometer LUS-B30
  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 2 nm
  • Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
  • Wavelength Repeatability : ≤ 0.1 nm
  • Optical system : Double beam 1200 lines/mm
Double Beam UV/Vis Spectrophotometer LUS-B31
  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 1 nm
  • Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
  • Wavelength Repeatability : ≤ 0.1 nm
  • Optical system : Double beam 1200 lines/mm

Double Beam UV/Vis Spectrophotometer LUS-B32

  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 0.5/1/2/4/5 nm
  • Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
  • Wavelength Repeatability : ≤ 0.1 nm
  • Optical system : Double beam 1200 lines/mm