×

Enquiry Form

info@labtron.us

Low Temperature Tester

Automatic Pour Point Tester LLTT-A23

  • Ambient temperature : ≤ 30 ℃
  • Refrigeration speed : > 40 °C / 10 min
  • Repeatability for solidifying point : ≤ 2 °C
  • Repeatability for pour point : ≤ 3 °C
  • Reproducibility : ± 4 °C

Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

  • Ambient temperature : (-10)℃ ~ 35 ℃
  • Relative humidity : ≤ 85 %
  • Sample cup Inner diameter : 31.0 ~ 32.0 mm
  • Sample cup Wall thickness : 1.0 ~ 1.5 mm
  • Sample cup Height : 115 ~ 125 mm

Freezing Point Tester LLTT-A11

  • Freezing point range : -54°C to 2°C
  • Cold bath measurement temperature range : -70° to 20°C
  • Temperature controlling accuracy : ±0.5°C
  • Bath liquids stirring : Electric
  • Bath liquids stirring range : 1200 r/min
Multifunctional Low Temperature Tester LLTT-A16
  • Refrigeration system : New-type refrigeration compressor
  • Controlling temperature of cold trough : Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C
  • Ambient temperature : ≤ 30 ℃
  • Relative humidity : ≤ 85 %
  • Dimensions : 930 x 570 x 108 mm
Pour and Cloud Point Tester LLTT-A14
  • Chamber quantity : 2 chambers
  • Chamber 01 temperature control : Ambient to -51 ℃
  • Chamber 02 temperature control : Ambient to -65 ℃
  • Temperature precision : ±1°C
  • Ambient temperature : ≤ 30°C

Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15

  • Refrigeration system : New-type refrigeration compressor
  • Controlling temperature of cold trough : Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
  • Ambient temperature : ≤ 30 ℃
  • Relative humidity : ≤ 85 %
  • Inner Dimensions : 560 x 380 x 250 mm

Solidifying Point Constant Temperature Water Bath LLTT-A10

  • Capacity : 20 L
  • Temperature range : Ambient +5°C to 100°C
  • Precision : ± 0.1℃
  • Stirring range : 1200 r/min
  • Heating : Two grades

Solidifying Point Tester ('-20°C +80°C') LLTT-A22

  • Temperature controlling accuracy : ± 0.5 °C
  • Refrigeration system : New-type refrigeration compressor
  • Cold trough : One trough with two baths, temperatures in two baths are equal
  • Controlling temperature of cold trough : Room temperature ~ (-70) °C
  • Temperature Range : 20 °C ~ 80 °C
Solidifying Point Tester (Solidifying Point and Cold Filter Plugging Point) LLTT-A21
  • Refrigeration system : New-type refrigeration compressor
  • Cold trough : One trough with two baths, temperatures in two baths are equal
  • Controlling temperature of cold trough : Room temperature ~ (-70) °C
  • Ambient temperature : ≤ 30 ℃
  • Relative humidity : ≤ 85 %
Solidifying Point Tester LLTT-A13
  • Temperature controlling accuracy : ± 0.5 ℃
  • Refrigeration system : New-type refrigeration compressor
  • Cold trough : Two holes in one trough, and same temperature
  • Ambient temperature : ≤ 30 ℃
  • Relative humidity : ≤ 85 %

Solidifying Point Tester LLTT-A20

  • Temperature controlling accuracy : ± 0.5 °C
  • Refrigeration system : New-type refrigeration compressor
  • Cold trough : One trough with two baths, temperatures in two baths are equal
  • Controlling temperature of cold trough : Room temperature ~ (-70) °C
  • Ambient temperature : ≤ 30 ℃