COD determination range | 2 to 10000 mg/ L |
COD measurement accuracy | COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 % |
COD minimum detection limit | 0.1 mg/ L |
COD measurement time | 20 minutes |
COD repeatability | ≤ ± 5 % |
Processing sample number per batch | |
Consumables for colorimetric COD measurement | Colorimetric tubes and Cuvette |
COD reactor digestion temperature | 165 ± 0.5°C |
COD reactor digestion time | 10 min |
COD reactor time setting switches | 3 pcs |
Anti-chlorine interference | (Cl) < 1000 mg/ L No effect |
Ammonia nitrogen determination range | 0.02 to 60 mg/ L |
Ammonia nitrogen measurement accuracy | ≤ ± 10 % |
Ammonia nitrogen minimum detection limit | 0.01 mg/ L |
Ammonia nitrogen measurement time | 10 to 15 minutes |
Ammonia nitrogen repeatability | ≤ ± 5 % |
Processing sample number per batch | |
Consumables for colorimetric ammonia nitrogen measurement | Colorimetric tubes and Cuvette |
Ammonia nitrogen reactor time setting switches | 3 pcs |
Total phosphorous determination range | 0.002 to 20 mg/ L |
Total phosphorous total phosphorous measurement accuracy | ≤ ± 5 % |
Total phosphorous minimum detection limit | 0.001 mg/ L |
Total phosphorous measurement time | 35 to 50 minutes |
Total phosphorous repeatability | ≤ ± 5 % |
Processing sample number per batch | |
Consumables for colorimetric total phosphorous measurement | Colorimetric tubes and Cuvette |
Total phosphorous reactor digestion temperature | 120 ± 0.5°C |
Total phosphorous reactor digestion time | 30 min |
Total phosphorous reactor time setting switches | 3 pcs |
Turbidity determination range | 0.5 to 400 NTU |
Turbidity measurement accuracy | ≤ ± 5 % |
Turbidity minimum detection limit | 0.1 NTU |
Turbidity measurement time | 1 minute |
Turbidity repeatability | ≤ ± 5 % |
Consumables for colorimetric turbidity measurement | Colorimetric Cuvette |
COD determination range | 5 to 5000 mg/ L |
COD measurement accuracy | COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 % |
COD minimum detection limit | 0.1 mg/ L |
COD measurement time | 20 minutes |
COD repeatability | ≤ ± 5 % |
Processing sample number per batch | 12 pcs |
Consumables for colorimetric COD measurement | Colorimetric tubes and Cuvette |
COD reactor digestion temperature | 165 ± 0.5°C |
COD reactor digestion time | 10 min |
COD reactor time setting switches | 3 pcs |
Anti-chlorine interference | (Cl) < 1000 mg/ L No effect |
Ammonia nitrogen determination range | 0.02 to 30 mg/ L |
Ammonia nitrogen measurement accuracy | ≤ ± 10 % |
Ammonia nitrogen minimum detection limit | 0.01 mg/ L |
Ammonia nitrogen measurement time | 10 to 15 minutes |
Ammonia nitrogen repeatability | ≤ ± 5 % |
Processing sample number per batch | 20 pcs |
Consumables for colorimetric ammonia nitrogen measurement | Colorimetric tubes and Cuvette |
Ammonia nitrogen reactor time setting switches | 3 pcs |
Total phosphorous determination range | 0.002 to 10 mg/ L |
Total phosphorous total phosphorous measurement accuracy | ≤ ± 5 % |
Total phosphorous minimum detection limit | 0.001 mg/ L |
Total phosphorous measurement time | 35 to 50 minutes |
Total phosphorous repeatability | ≤ ± 5 % |
Processing sample number per batch | 12 pcs |
Consumables for colorimetric total phosphorous measurement | Colorimetric tubes and Cuvette |
Total phosphorous reactor digestion temperature | 120 ± 0.5°C |
Total phosphorous reactor digestion time | 30 min |
Total phosphorous reactor time setting switches | 3 pcs |
Turbidity determination range | 0.5 to 400 NTU |
Turbidity measurement accuracy | ≤ ± 5 % |
Turbidity minimum detection limit | 0.1 NTU |
Turbidity measurement time | 1 minute |
Turbidity repeatability | ≤ ± 5 % |
Consumables for colorimetric turbidity measurement | Colorimetric Cuvette |