Enquiry Form

info@labtron.us

Plastic Testing Instruments

Aging Oven TAO-A10

  • The maximum temperature : 300°C
  • Temperature fluctuation : Within ± 0.5°C
  • Temperature uniformity : Within ± 1°C
  • Rotate speed of the turntable : 11 r/min to 12r/min, turntable dimension diameter: 285 mm
  • Quantity of heaters : 2 pcs

Charpy/ Izod Impact Tester TCI-A10

  • Impact Speed & Energy (charpy) : 2.9 m/s for 1J, 2J, 4J, 5J & 3.8 m/s for 7.5J, 15J, 25J
  • Impact energy (Izod) : 3.5 m/s for 1J, 2J, 4J, 5J, 7.5J, 15J, 25J
  • Resolution of impact energy : 0.001 J
  • Pendulum up angle : 160°
  • Impact center distance (Charpy) : 221 mm for 1J, 2J, 4J, 5J & 380 mm 7.5J, 15J, 25J

Falling Weight Impact Tester TFWT-A10

  • Temperature range : 10 to 35°C
  • Maximum falling height : 2000 mm
  • Resolution of displacement : 1 mm
  • Height error : < ± 2 mm
  • Hammer mass : 0.25 to 16 kg
Heat sealer THS-A10
  • Seal temperature : Room temperature -250°C
  • Control accuracy : ± 0.2°C
  • Dwell time : 0.1 S to 999.9 S
  • Dwell pressure : 0.05 to 0.7 MPa
  • Heating mode : Single and double heating surface
Lasting adhesive tester TLAT-A10
  • Standard roller : 2000 ± 50 g
  • Testing stations : 3
  • Dimension (L*W*H) tester : 320×210×550 mm (3 stations)
  • Weight for stations : 10 kg (3 stations)
  • Weight of the plates : 1000 ± 3 g ( with triangle hook)

Lasting adhesive tester TLAT-A11

  • Standard roller : 2000 ± 50 g
  • Testing stations : 6
  • Dimension (L*W*H) tester : 650×210×550 mm (6 stations)
  • Weight for stations : 15 kg (6 stations)
  • Weight of the plates : 1000 ± 3 g ( with triangle hook)

Melt flow Indexer TMFI-A10

  • Measuring range : 0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density)
  • Measuring rate : 0.001 S
  • Temperature range : 50 to 400°C
  • Temperature precision : ± 0.5°C
  • Resolution : 0.1°C

Melt flow Indexer TMFI-A11

  • Measuring range : 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)
  • Measuring rate : 0.001 S
  • Temperature range : 50 to 400°C
  • Temperature precision : ± 0.5°C
  • Resolution : 0.1°C
Oxygen Index Tester TOIT-A10
  • Resolution : 0.1 % O2
  • Measuring range : 0 to 100 % O2
  • Precision : ± 0.4 % O2
  • Response time : < 10 S
  • Display precision : 0.1 ± 1 %
Primary adhesive tester TPAT-A10
  • Inclined adjustable angle : 0 to 40°
  • Panel width : 120 mm
  • Test area width : 80 mm
  • Standard steel balls : 1/32 to 1 inch
  • Dimension (L*W*H) : 320×140×180 mm

Vacuum Leak Tester TVLT-A10

  • Vacuum degree : 0 to 90 KPa
  • Accuracy : 1 % FS
  • Resolution : 0.1 KPa
  • Vacuum chamber effective size : 270 × 210 mm
  • Vacuum chamber size : 300 × 350 mm

Vicat softening temperature & HDT machine TVHT-A10

  • Operating temperature : Ambient temperature to 300°C
  • Heating rate : 50°C/ h (5 ± 0.5°C/ 6 min) , 120°C/ h (12 ± 1°C/ 6 min)
  • Maximum temp. error with heating speed : ± 5°C under 50°C/ h, ± 1°C under 120°C/ h
  • Range of deformation : 0 to 10 mm
  • Deformation measurement method : Digi gauge