Conductivity measurement range | 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm |
Conductivity accuracy | ±0.5% F.S |
Conductivity calibration points | 1 to 3 points |
Conductivity calibration solutions | 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom |
Conductivity resolution | 0.001, 0.01, 0.1, 1 |
Temperature measuring range | 0 105 °C, 32 to 221 °F |
Temperature measuring accuracy | ± °0.5 C, ± 0.9 °F |
Temperature calibration points | 1 point |
Temperature resolution | 0.1 °C, 0.1 °F |
Conductivity measurement range | 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm |
Conductivity accuracy | ±0.5% F.S |
Conductivity calibration points | 1 to 5 points |
Conductivity calibration solutions | 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom |
Conductivity resolution | 0.001, 0.01, 0.1, 1 |
TDS range | 0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt) |
TDS accuracy | ±1 % F.S |
TDS factor | 0.01 to 1.00 (Default 0.5) |
TDS resolution | 0.01, 0.1, 1 |
Temperature measuring range | 0 105 °C, 32 to 221 °F |
Temperature measuring accuracy | ± °0.5 C, ± 0.9 °F |
Temperature calibration points | 1 point |
Temperature resolution | 0.1 °C, 0.1 °F |
Conductivity measurement range | 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm |
Conductivity accuracy | ±0.5% F.S |
Conductivity calibration points | 1 to 5 points |
Conductivity calibration solutions | 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom |
Conductivity resolution | 0.001, 0.01, 0.1, 1 |
Salinity range | 0.00 to 80.00 ppt, 0.00 to 42.00 psu |
Salinity accuracy | ±1% F.S |
Salinity measurement modes | Practical Salinity (psu) or Natural Seawater (ppt) |
Salinity resolution | 0.01, 0.1, 1 |
Temperature measuring range | 0 105 °C, 32 to 221 °F |
Temperature measuring accuracy | ± °0.5 C, ± 0.9 °F |
Temperature calibration points | 1 point |
Temperature resolution | 0.1 °C, 0.1 °F |
Conductivity measurement range | 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm |
Conductivity accuracy | ±0.5% F.S |
Conductivity calibration points | 1 to 5 points |
Conductivity calibration solutions | 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom |
Conductivity resolution | 0.001, 0.01, 0.1, 1 |
TDS range | 0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt) |
TDS accuracy | ±1 % F.S |
TDS factor | 0.01 to 1.00 (Default 0.5) |
TDS resolution | 0.01, 0.1, 1 |
Salinity range | 0.00 to 80.00 ppt, 0.00 to 42.00 psu |
Salinity accuracy | ±1% F.S |
Salinity measurement modes | Practical Salinity (psu) or Natural Seawater (ppt) |
Salinity resolution | 0.01, 0.1, 1 |
Resistivity range | 0.00 to 20 MΩ |
Resistivity accuracy | ±1% F.S |
Resistivity resolution | 0.01, 0.1, 1 |
Temperature measuring range | 0 105 °C, 32 to 221 °F |
Temperature measuring accuracy | ± °0.5 C, ± 0.9 °F |
Temperature calibration points | 1 point |
Temperature resolution | 0.1 °C, 0.1 °F |