Enquiry Form

info@labtron.us

Rotational Viscometers

Viscometer LVM-A10

  • Measuring range : 1 - 6,000,000 cP, 100 - 40,000,000 cP, 200 - 80,000,000 cP, 800 - 320,000,000 cP
  • Rotating speed : 0.1 - 200 rpm
  • Measuring Error (Newtonian liquid) : ± 1.0 % full range
  • Repeatability error (Newtonian liquid)) : ± 0.5 %
  • Power : 100 / 240 V

Viscometer LVM-A20

  • Viscosity Range : LV: 1 to 2000000 mPa.s
  • Rotation speed range : 0.3 to 100 rpm (stepless)
  • Spindles : LV: (1#, 2#, 3#, 4# spindles) (0# is optional)
  • Accuracy : ± 1.0 % (of full range)
  • Repeatability : 0.005

Viscometer LVM-A21

  • Viscosity Range : RV: 100 to 13000000 mPa.s
  • Rotation speed range : 0.3 to 100 rpm (stepless)
  • Spindles : RV: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
  • Accuracy : ± 1.0 % (of full range)
  • Repeatability : 0.005
Viscometer LVM-A22
  • Viscosity Range : HA: 200 to 26000000 mPa.s
  • Rotation speed range : 0.3 to 100 rpm (stepless)
  • Spindles : HA: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
  • Accuracy : ± 1.0 % (of full range)
  • Repeatability : 0.005
Viscometer LVM-A23
  • Viscosity Range : HB: 800 to 104000000 mPa.s
  • Rotation speed range : 0.3 to 100 rpm (stepless)
  • Spindles : HB: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
  • Accuracy : ± 1.0 % (of full range)
  • Repeatability : 0.005

Viscometer LVM-A30

  • Viscosity Range : LV: 1 to 6000000 mPa.s
  • Rotation speed range : 0.1 to 250 rpm
  • Spindles : (1#, 2#, 3#, 4# spindles) (0# is optional)
  • Accuracy : ± 1.0% (of full range)
  • Repeatability : 0.005

Viscometer LVM-A31

  • Viscosity Range : RV: 100 to 40000000 mPa.s
  • Rotation speed range : 0.1 to 250 rpm
  • Spindles : (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
  • Accuracy : ± 1.0% (of full range)
  • Repeatability : 0.005

Viscometer LVM-A40

  • Viscosity Range : 3 to 1600000 M (mPa.s)
  • Rotation speed range : 0.3/0.6/1.5/3/6/10/12/15/20/25/30/40/50/60/70/80/90/100 Total 18 rpm
  • Spindles : 18# rotor:3 to 10 K; 7 ml 25# rotor:480 to 1.6 M; 9 ml 31# rotor:30 to 100 K; 10.5 ml 34# rotor:60 to 200 K; 11 ml
  • Rotor : 18#,25#,31#,34# (standard configuration)
  • Accuracy : ±3%  (Newtonian liquid)
Viscometer LVM-A41
  • Rotational speed range : 0.3 to 100 rpm
  • Standard Rotor : Rotor R2 to R7 (6, Standard), R1 (Apolegamy)
  • Viscosity measurement range : Rotor R2 to R7:100 to 4000 M (mPa.s)
  • Standard Rotor Sample Dosage : Rotor R1 to R7: 500 ml
  • Measurement error : ± 1 %
Viscometer LVM-A42
  • Rotational speed range : 0.3 to 100 rpm
  • Standard Rotor : Rotor R2 to R7 (6, Standard), R1 (Apolegamy)
  • Viscosity measurement range : Rotor R2 to R7:200 to 26 M (mPa.s)
  • Standard Rotor Sample Dosage : Rotor R1 to R7: 500 ml
  • Measurement error : ± 1 %

Viscometer LVM-B10

  • Measuring range : 0.1 to 100,000 mPa.s
  • Rotating speed : 6/12/30/60 (r/min)
  • Rotor : 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
  • Measuring Error (Newtonian liquid) : ±1%
  • Repeatability error (Newtonian liquid)) : ±0.5%

Viscometer LVM-B11

  • Measuring range : 0.1 to 2,000,000 mPa.s
  • Rotating speed : 0.3/0.6/1.5/3/6/12/30/60 (r/min)
  • Rotor : 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
  • Measuring Error (Newtonian liquid) : ±1%
  • Repeatability error (Newtonian liquid)) : ±0.5%

Viscometer LVM-C10

  • Measuring range : 1 to 100000 mPa.s
  • Rotating speed : 3/6/12/30/60 (r/min)
  • Rotor : 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
  • Measuring Error (Newtonian liquid) : ±1%
  • Repeatability error (Newtonian liquid)) : ±0.5%
Viscometer LVM-C11
  • Measuring range : 1 to 100000 mPa.s
  • Rotating speed : 3/6/12/30/60 (r/min)
  • Rotor : 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
  • Measuring Error (Newtonian liquid) : ±0.5%
  • Repeatability error (Newtonian liquid)) : ±0.25%
Viscometer LVM-C12
  • Measuring range : 1 to 200000 mPa.s
  • Rotating speed : 0.3/0.6/1.5/3.6/12/30/60 (r/min)
  • Rotor : 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
  • Measuring Error (Newtonian liquid) : ±1%
  • Repeatability error (Newtonian liquid)) : ±0.5%

Viscometer LVM-C13

  • Measuring range : 1 to 600000 mPa.s
  • Rotating speed : 0.1/0.3/0.6/1.5/3/6/12/30/60 (r/min)
  • Rotor : 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
  • Measuring Error (Newtonian liquid) : ±1%
  • Repeatability error (Newtonian liquid)) : ±0.5%

Viscometer LVM-D10

  • Measurement range : 25 mPa.s to 1×10000000 mPa.s
  • Rotors : Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
  • Rotor speed : (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/min
  • Temperature control range : 45 to 200°C
  • Temperature control accuracy : ± 0.1°C

Viscometer LVM-D11

  • Measurement range : 100 mPa.s to 200000 mPa.s
  • Rotors : Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
  • Rotor speed : 5, 10, 20, 50 r/min
  • Temperature control range : Room temperature to 200°C
  • Temperature control accuracy : ± 0.1°C
Viscometer LVM-D12
  • Measurement range : 100 mPa.s to 2000000 mPa.s
  • Rotors : Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
  • Rotor speed : 5, 10, 20, 50 r/min
  • Temperature control range : 45 to 200°C
  • Temperature control accuracy : ± 0.1°C
Viscometer LVM-D20
  • Viscosity Range : 40.2 KU to 141.0 KU
    32 g to 1099 g
    27 to 5250 CP
  • Rotation speed range : 200±0.1 rpm
  • Accuracy : ± 3 %
  • Repeatability : ±1.5 %
  • Measuring container : 1 pint