Analytical HPLC-A7840 system with 0.001 to 9.999 ml / min flow rate range, offers three method measurement: dual wavelength detection, wavelength time program and stop pump scanning. Integrated with a single and dual wavelength UV-Vis detector with a range of 190 to 700 nm to analyse sample’s absorption at different wavelengths and high-pressure pump achieves accurate solvent delivery with high-precision and low-fluctuation.
Specifications :
| Pump Specifications |
| Solvent delivery |
Double plunger series mode, floating plunger design, single stroke volume 30 µl |
| Pump Head |
10 ml stainless steel pump head |
| Flow rate range |
0.001 to 9.999 ml / min |
| Flow rate increment |
0.001 ml/min |
| Maximum pressure |
42 MPa |
| Column size |
4.6 × 250 mm 5 µm |
| Pipeline Size |
1/16 inch |
| Flow rate accuracy |
± 0.5 % |
| Flow rate precision |
RSD ≤ 0.1% |
| Gradient accuracy % |
± 0.5 % |
| Gradient repeatability % |
RSD ≤ 0.15% |
| GLP |
Automatic recording of pump sealing ring working time |
| Display |
LCD backlight display |
| Power |
80 W |
| Power supply |
220 V ± 10%, 50 Hz |
| Dimension |
398 × 149 × 267 mm |
|
| Detector Specifications |
| Wavelength range |
190 to 700 nm |
| Wavelength accuracy |
± 1 nm |
| Wavelength repeatability |
0.2 nm |
| Deuterium lamp |
190 to 400 nm |
| Tungsten lamp |
400 to 700 nm |
| Baseline noise ( Static ) Au |
1 × 10-5 AU/h at 254 nm with methanol/water= 80/20 |
| Baseline drift ( Static ) Au / h |
1.5 × 10-4 AU/h at 254 nm with methanol/ water= 80/20 |
| Time constants |
16 grades adjustable |
| Display |
LCD backlight display |
| GLP |
Total number of lights, lamp replacement time and product serial number |
| Power |
75 W |
| Power supply |
220 V ± 10%, 50 Hz |
| Dimension (L × W × H) |
398 × 149 × 267 mm |
|
Features :
- - Floating plunger support mechanism improve plunger and seal ring
- - Detector (Deuterium or tungsten lamp)
- - Simultaneous working of deuterium and tungsten lamp
- - Three method measurement: dual wavelength detection, wavelength time program and stop pump scanning
- - Independent mode all working parameter are set by panel button
- - External pump control by panel or computer software
- - Quaternary high pressure gradient support
- - Error alarm function for over pressure ,under pressure and leakage
Applications :
Used in pharmaceutical analysis, food nutrient analysis of amino acids and sugars, detection of food contaminants, environmental pollutant and chemical product purity analysis.
Standard Accessories :
| Accessories no. |
Accessories name |
Specification |
Unit |
| 1 |
Analytical pump |
10 ml/min, 42 MPa |
2 |
| 2 |
Analytical UV detector |
Analytical flow cell included |
1 |
| 3 |
Chromatography software |
FDA compliance |
1 |
| 4 |
Start-up kits |
Accessories and tools |
1 |
| 5 |
Static mixer |
Analytical mixing |
1 |
| 6 |
Manual injection valve |
ID 4.6 × 250 mm 5 µm C18 kromasil |
1 |