| Maximum capacity | 22 L |
| Temperature range | RT + 5 ℃ to 400 ℃ |
| Temperature accuracy | ± 0.1 ℃ |
| Temperature program | 9-phase/ 10 platform |
| Program total time | 9999.9 min |
| Maximum temperature heating rate | 0.1 to 60 ℃/ min |
| Maximum cooling rate | ˂ 10 mins (250 to 50 ℃) |
| Temperature range | RT+ 7 ℃ to 420 ℃ |
| Temperature control | Automatic |
| Injector type | Column or split |
| Maximum sample inlet | 3 pcs |
| Carrier gas flow type | Constant pressure |
| Pre column pressure range | 0 to 400 kPa |
| Pre column pressure accuracy | 0.1 kPa |
| Mobile phase flow range | H2: 0 to 200 ml/min, N2: 0 to 150 ml/min |
| Temperature range | RT + 7 ℃ to 420 ℃ |
| Maximum installation | Dual detector |
| Flame ignition mode | Automatic |
| Flame Ionization Detector (FID) | Logarithmic amplifier High voltage switch control Baseline signal display Ignition coil control Detection limit: ≤3 ×10 to 12 g/s (Sample: n-hexadecane) Baseline noise: ≤ 5 × 10 - 14 A Baseline draft: ≤ 6 × 10 -13 A Dynamic range: 10 7 RSD: ≤ 3 % |
| Model No | GC-87 |
| Flow rate | 1 ~ 1.5 ml / min |
| Maximum flow rate | 10 ml / min |
| Inlet temperature | 450 °C |
| Pressure range | 0 ~ 100 psi |
| Heating rate | Upto 120 °C / min |
| Room temperature | 4 °C ~ 450 °C |
| Pressure control mode | Electronic pressure control ( Supports CV and CC ) |
| Split mode | Split / split less |
| Split ratio | 1000 : 1 |
| Temperature programming | 7 stages / 8 platforms |
| Auto sampler | Optional |
| Model No | MS-89 |
| Mass range | 1.5 ~ 1000 amu |
| Ion – source temperature | 100 °C ~ 350 °C |
| GC-MS interface temperature | 450 °C |
| Scan rate | Upto 10000 amu/s |
| Stability | ± 0.10 amu / 48 hrs. |
| Filament emission current | 0 ~ 350 µA |
| EI source ionization energy | 5 eV ~ 250 eV |
| Resolution | Unit resolution |
| Detector | High energy dynode electron multiplier |
| Sensitivity | Full scan ( S / N is ≥ 30 : 1 ) |
| Vacuum | Turbo molecular pump ( 67 L/s ) |
| Type | High-pressure and low –pulse double plunger tandem advection pump |
| Maximum Pressure | 35 MPa (PEEK) |
| Flow Range | 0.001 to 9.999 mL/min |
| Flow accuracy | ± 0.5 % |
| Flow Repeatability | RSD ≤ 0.1% |
| Flow stability | (0.2 to 0.5) mL/min, ≤ 3 % (0.5 to 1.0) mL/min, ≤ 2 % >1.0 mL/min, ≤ 2 % |
| Temperature range | Room temperature +5°C to 60°C (41 to 140°F) |
| Allowable deviation | ± 1°C |
| Temperature stability | ≤ 0.5°C/h |
| Maximum pressure | 35 MPa |
| Control mode | By stepper motor |
| Power supply | 24 V (DC) |
| Type | Temperature control and bipolar conductivity detector |
| Detection type | Bipolar conductivity detection |
| Cell volume | ≤ 0.8 µL |
| Measurement range | 0 to 45000 µ S/cm (adjustable) |
| Detection resolution | ≤ 0.0020 nS/cm |
| Output voltage | -6000 to 6000 mV (adjustable) |
| Temperature range | Room temperature +5°C to 60°C (41 to 140°F) |
| Temperature accuracy | ± 0.01°C |
| Maximum pressure | 10 MPa |
| Baseline drift | ≤ 20 % FS/30 min |
| Baseline noise | ≤0.5 % FS |
| Instrument linearity | ≥ 0.999 |
| Quantitative Repeatability | ≤0.5 % |
| Qualitative Repeatability | ≤2 % |
| Minimum detectable concentration | Cl-≤0.005 µg/mL Li+ ≤0.005 µg/mL |
| Plastic path flow | Made of PEEK material |
| Six way valve | PEEK material pressure 5000 psi, independent automatic collecting and flow function |
| Type | High pressure and low pulse double plunger tandem advection pump |
| Maximum pressure | 35 MPa (PEEK) |
| Pressure display accuracy | ≤ 0.1 MPa |
| Flow stability | (0.2 to 0.5) ml/ min ≤ 3 % (0.5 to 1.0) ml/ min ≤ 2 % > 1.0 ml/ min 2 % |
| Flow range | 0.001 to 9.999 ml/ min |
| Pressure pulse | ≤ 0.5% |
| Type | Temperature Control and Bipolar Conductivity Detector |
| Detection mode | Bipolar conductivity detection |
| Cell volume | ≤ 0.8 µL |
| Detection range | 0 to 35000 µS/ cm |
| Detection resolution | ≤ 0.0020 nS/ cm |
| Output voltage | - 6000 to +6000 mV (adjustable) |
| Baseline noise | ≤ 0.05 % F.S. |
| Baseline drift | ≤ 3 % FS/ 30 min |
| Operating temperature range | Room temperature +5 to 60°C (41 to 140°F) |
| Controlling temperature accuracy | ± 0.01°C |
| Maximum pressure | 10 MPa |
| Linear range | ≥ 103 |
| Instruments linearity | ≥ 0.999 |
| Quantitative repeatability | ≤ 1.0 % |
| Qualitative repeatability | ≤ 1.0 % |
| Minimum detectable concentration | Cl ≤ 0.0005 ug/ ml BrO3 ≤ 0.001 ug/ ml Li+ ≤ 0.001 ug/ ml |
| Plastic flow path | Made of PEEK materials |
| Six way Valve | PEEK material, 5000 psi pressure, independent automatic collection and flow function |
| Inner volume | 300 µl |
| Degassing volume | 7.5 ml |
| Maximum flow rate | 10 ml/ min |
| Degassing efficiency | Degassing 90 % at 1ml/ min |
| Organic tolerance | 1 |
| Eluent types | KOH/ NaOH |
| Eluent concentration range | 0.1 to 100 mM |
| Concentration increment | 0.1 mM |
| Flow rate change | 0.1 to 3.0 ml/ min |
| Maximum pressure | 20 MPa |
| Minimum pressure | 5 MPa |
| Type | High pressure and low pulse double plunger tandem advection pump |
| Maximum pressure | 35 MPa (PEEK) |
| Pressure display accuracy | ≤ 0.1 MPa |
| Flow stability | (0.2 to 0.5) ml/ min ≤ 3 % (0.5 to 1.0) ml/ min ≤ 2 % > 1.0 ml/ min 2 % |
| Flow range | 0.001 to 9.999 ml/ min |
| Pressure pulse | ≤ 0.5% |
| Type | Temperature Control and Bipolar Conductivity Detector |
| Detection mode | Bipolar conductivity detection |
| Cell volume | ≤ 0.8 µL |
| Detection range | 0 to 45000 µS/ cm |
| Detection resolution | ≤ 0.0020 nS/ cm |
| Output voltage | - 6000 to +6000 mV (adjustable) |
| Baseline noise | ≤ 0.05 % F.S. |
| Baseline drift | ≤ 3 % FS/ 30 min |
| Operating temperature range | Room temperature +5 to 60°C (41 to 140°F) |
| Controlling temperature accuracy | ± 0.01°C |
| Maximum pressure | 10 MPa |
| Linear range | ≥ 103 |
| Instruments linearity | ≥ 0.999 |
| Quantitative repeatability | ≤ 1.0 % |
| Qualitative repeatability | ≤ 1.0 % |
| Minimum detectable concentration | Cl ≤ 0.0005 ug/ ml BrO3 ≤ 0.001 ug/ ml Li+ ≤ 0.001 ug/ ml |
| Plastic flow path | Made of PEEK materials |
| Six way Valve | PEEK material, 5000 psi pressure, independent automatic collection and flow function |
| Type | High pressure and low pulse double plunger tandem advection pump |
| Maximum pressure | 35 MPa (PEEK) |
| Display pressure accuracy | ≤ 0.1 MPa |
| Flow stability | (0.2 to 0.5) ml/ min ≤ 3 % , (0.5 to 1.0) ml/ min ≤ 2 %, > 1.0 ml/ min ≤ 2 % |
| Flow range | 0.001 to 9.999 ml/ min |
| Pressure pulse | ≤ 0.5 % |
| Maximum pressure | 35 MPa |
| Contact material of the rotor | PEEK |
| Control mode | By Stepper motor |
| Power supply | DC 24 V |
| Operating temperature range | Room temperature 20 to 60°C ( 68 to 140°F) |
| Controlling temperature accuracy | ± 0.01°C |
| Allowable deviation of column heater temperature | ± 2°C |
| Temperature stability | ≤ 1°C/ h |
| Plastic flow path | Made up of PEEK material |
| Six way valve | PEEK material pressure 5000 psi, independent automatic collection and flow function |
| Temperature range | 25 to 40°C ( 77 to 104°F) |