Disintegration tester LDIT-A10
  • Number of basket lifting set : 1 set
  • Lifting frequency of the basket : 30 to 32/ min
  • Lifting distance of basket : 55 ± 1 mm
  • Minimum spacing from screen to bottom of beaker : 25 ± 2 mm
  • Mesh size : 2 mm (as per standard configuration )
Disintegration tester LDIT-A11
  • Number of basket lifting set : 2 sets
  • Lifting frequency of the basket : 30 to 32/ min
  • Lifting distance of basket : 55 ± 1 mm
  • Minimum spacing from screen to bottom of beaker : 25 ± 2 mm
  • Mesh size : 2 mm (as per standard configuration )
Disintegration tester LDIT-A12
  • Number of basket lifting set : 3 sets
  • Lifting frequency of the basket : 30 to 32/ min
  • Lifting distance of basket : 55 ± 1 mm
  • Minimum spacing from screen to bottom of beaker : 25 ± 2 mm
  • Mesh size : 2 mm (as per standard configuration )
Dissolution tester LDLT-A10
  • No of vessels : 1
  • No of poles : 1
  • Position of vessels and poles : One vessel and one pole arranged on one line
  • Head part movement : Manually turn over
  • Preset time (for 9 points) : 5 to 900 mins
Dissolution tester LDLT-A11
  • No of vessels : 3
  • No of poles : 3
  • Position of vessels and poles : Three vessel and three pole arranged on one line
  • Head part movement : Manually turn over
  • Preset time (for 9 points) : 5 to 900 mins
Dissolution tester LDLT-A12
  • No of vessels : 6
  • No of poles : 6
  • Position of vessels and poles : Six vessel and six pole arranged on one line
  • Head part movement : Manually turn over
  • Preset time (for 9 points) : 1 to 999 mins
Dissolution tester LDLT-A13
  • No of vessels : 6
  • No of poles : 6
  • Position of vessels and poles : Six vessel and six pole arranged on one line
  • Head part movement : Electrically turn over
  • Preset time (for 9 points) : 1 to 999 mins
Dissolution tester LDLT-A14
  • No of vessels : 8
  • No of poles : 6
  • Position of vessels and poles : Six vessels and six poles in front and other two vessels at back
  • Head part movement : Manually turn over
  • Preset time (for 9 points) : 1 to 999 mins
Dissolution tester LDLT-A15
  • No of vessels : 8
  • No of poles : 6
  • Position of vessels and poles : Six vessels and six poles in front and other two vessels at back
  • Head part movement : Electrically turn over
  • Preset time (for 9 points) : 1 to 999 mins
Dissolution tester LDLT-A16
  • No of vessels : 8
  • No of poles : 8
  • Position of vessels and poles : Four vessels and four poles in front and others at back
  • Head part movement : Electrically turn over
  • Preset time (for 9 points) : 1 to 999 mins
Dissolution tester LDLT-A17
  • No of vessels : 12
  • No of poles : 12
  • Position of vessels and poles : Six vessels and six poles in front and other six poles and vessels at back
  • Head part movement : Electrically (automatic) turn over
  • Preset time : 1 to 999 mins
Friability Tester LTFT-A10
  • Number of cylinder : 2
  • Rotating speed of cylinders : 25 rpm
  • Rotating accuracy : ± 1 rpm
  • Counting mode : Adopted with countdown, 100 turns can be set arbitrarily
  • Inner diameter of cylinder : 286 mm
Friability Tester LTFT-A11
  • Number of cylinder : 2
  • Rotating speed of cylinders : 20 to 100 rpm can be set arbitrarily
  • Rotating accuracy : ± 1 rpm
  • Counting mode : Adopted with countdown, 5 to 900 turns can be set arbitrarily
  • Inner diameter of cylinder : 286 mm
Friability Tester LTFT-A12
  • Number of cylinder : 2
  • Rotating speed of cylinders : 25 rpm can be set arbitrarily
  • Rotating accuracy : ± 1 rpm
  • Counting mode : Adopted with countdown, 5 to 900 turns can be set arbitrarily
  • Inner diameter of cylinder : 286 mm
Friability Tester LTFT-A13
  • Number of cylinder : 1
  • Rotating speed of cylinders : 25 rpm
  • Rotating accuracy : ± 1 rpm
  • Counting mode : 10 to 900 turns can be set arbitrarily
  • Inner diameter of cylinder : 286 mm
Powder Flowability Tester LPFL-A10
  • Disc : Diameter 100 mm
  • Funnel Outer Diameter : Outer diameter 155 mm
  • Funnel Inner Diameter : 145 mm
  • Test Sample : Surfactant Powder and Particles, non-agglomerated powder
  • Angle of Repose : 30° (recommended)
Single Punch Tablet Press Machine LSTP-A10
  • Maximum pressure : 60 KN
  • Maximum diameter Tablet : 25 mm
  • Maximum depth of filling : 16 mm
  • Maximum thickness of tablet : 10 mm
  • Production capacity : 2500 PC/h
Single Punch Tablet Press Machine LSTP-A11
  • Maximum pressure : 50 KN
  • Maximum diameter Tablet : 20 mm
  • Maximum depth of filling : 12 mm
  • Maximum thickness of tablet : 6 mm
  • Production capacity : 4000 PC/h
Single Punch Tablet Press Machine LSTP-A12
  • Maximum pressure : 15 KN
  • Maximum diameter Tablet : 12 mm
  • Maximum depth of filling : 11 mm
  • Maximum thickness of tablet : 6 mm
  • Production capacity : 5000 PC/h
Syrup Filling Machine LSFM-A10
  • Material Stainless : 316 L Stainless Steel
  • Automatic Grade : Semi-Automatic
  • Power Source : Pneumatic
  • Filling Head : Single Head or Double Head or Customized
  • Air Pressure : 0.4MPa
Tablet Counting Machine LTCM-A10
  • Diameter of counting plate : 400 mm
  • Hole No. of counting slide/range : 5 to 100 (optional)
  • Production efficiency : 10 to 20 vials/ min
  • Rate of Bottles : 36 bottles/ minute
  • Vibration frequency : < 20 dB
Tablet Hardness tester LTHT-A10
  • Hardness measurement range : 2 to 196 N, 0.2 to 20 kg
  • Tablet diameter : 2 to 20 mm
  • No. of testing tablets in each group : ≤ 100 tablets
  • Built in printer : No
  • Resolution : 0.1N, 0.01 kg
Tablet Hardness tester LTHT-A11
  • Hardness measurement range : 2 to 200 N, 0.2 to 20 kg
  • Tablet diameter : 2 to 40 mm
  • No. of testing tablets in each group : ≤ 100 tablets
  • Built in printer : No
  • Resolution : 0.1N, 0.01 kg
Tablet Hardness tester LTHT-A12
  • Hardness measurement range : 2 to 200 N, 0.2 to 20 kg
  • Tablet diameter : 2 to 40 mm
  • No. of testing tablets in each group : ≤ 100 tablets
  • Built in printer : Yes
  • Resolution : 0.1N, 0.01 kg
Tap Density Tester LTDT-A10
  • Work Station : 1
  • Sample Volume : ≤ 250 ml
  • Sample Weight : ≤ 500 g
  • Number of Tapping : 0 to 99999 (set 0 to output bulk density)
  • Frequency : 300 rpm (continuous adjustable in 0 to 300 rpm)
Tap Density Tester LTDT-A11
  • Work Station : 2
  • Sample Volume : ≤ 250 ml
  • Sample Weight : ≤ 500 g
  • Number of Tapping : 0 to 99999 (set 0 to output bulk density)
  • Frequency : 300 rpm (continuous adjustable in 0 to 300 rpm)
Tap Density Tester LTDT-A12
  • Work Station : 3
  • Sample Volume : ≤ 100 ml
  • Sample Weight : ≤ 500 g
  • Number of Tapping : 0 to 99999 (set 0 to output bulk density)
  • Frequency : 300 rpm (continuous adjustable in 0 to 300 rpm)