info@labtron.us
Labtron
Request Quote

Airborne Particle Counters

Handheld Airborne Particle Counter LHPC-A11

  • Particle size channels : 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm
  • Flow rate : 0.1 CFM ( 2.83 L/min )
  • Test class : Class 100 ∼ Class 300,000
  • Test period : 1 min ∼ 15 min ( 15 levels )
  • UCL calculation : 0.95

Portable Airborne Particle Counter LPPC-A10

  • Particle size channels : 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
  • Flow Rate : 0.1 CFM ( 2.83 L/min )
  • Test class : Class 100 ∼ Class 300,000
  • Built-in battery : No
  • Test period : 1 min ∼ 10 min ( 10 levels )
Portable Airborne Particle Counter LPPC-A11
  • Particle size channels : 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
  • Flow Rate : 0.1 CFM ( 2.83 L/min )
  • Test class : Class 100 ∼ Class 300,000
  • Built-in battery : Yes
  • Test period : 1 min ∼ 10 min ( 10 levels )
Portable Airborne Particle Counter LPPC-A20
  • Particle size channels : 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
  • Flow Rate : 1 CFM ( 28.3 L/min )
  • Test class : Class 100 ∼ Class 300,000
  • Test period : 1 min ∼ 10 min
  • UCL Calculation : 0.95

Portable Airborne Particle Counter LPPC-A21

  • Particle size channels : 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm<hr> 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm
  • Flow Rate : 0.1 CFM ( 2.83 L/min )
  • Test class : Class 100 ∼ Class 300,000
  • Test period : 1 min ∼ 10 min
  • UCL Calculation : 0.95

Portable Airborne Particle Counter LPPC-A30

  • Size channel : 0.1, 0.2, 0.3, 0.5, 1.0, 5.0 (µm)
  • Flow rate : 28.3 L/min
  • Teat way : UCL
  • Test period : 1 to 40 minute
  • Zero count : < = 10 min
Portable Airborne Particle Counter LPPC-B10
  • Particle size channels : 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
  • Flow Rate : 1.0 CFM ( 28.3 L/min )
  • Sensitivity : 0.3 µm
  • Test period : 1 sec ∼ 5999 sec ( 5 L ∼ 3000 L )
  • Max. permissible sampling concentration : 35,000 pcs/L
Dual Flow Particle Counter LDPC-A10
  • Particle size channels : 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm<hr> 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm
  • Flow rates : 2.83 L/min<hr> 50 mL/min
  • Sensitivity : 0.3 µm
  • Test class : Class 100 ∼ Class 300,000
  • Test period : 1 min ∼ 10 min ( 10 levels )

Dust Monitor LDMR-A10

  • Particulate matter concentration : PM<sub>10</sub>, PM<sub>2.5</sub>, PM<sub>1.0</sub>, TSP
  • Particulate channels and size : 15 channels, 0.3 to 25 µm
  • Sensitivity : 0.0001 mg/m<sup>3</sup>
  • Measuring Range : 0.01 to 20 mg/m<sup>3</sup>
  • Accuracy : ± 10%

Handheld Dust Meter LDMH-A10

  • Measurement range : PM 1.0, PM 2.5, and PM 10.0
  • Resolution : 0.1 µg/m<sup>3</sup>
  • Concentration limits : 1000 µg/m<sup>3</sup>
  • Accuracy : 0.1
  • Flow rate : 2.83 L/min