×

Enquiry Form

info@labtron.us

Spectrophotometer

Atomic Absorption Spectrophotometer LAAS-A11
  • Wavelength range : 190 - 900 nm
  • Spectral Bandwidth : 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
  • Wavelength accuracy : ≤ ± 0.5 nm
  • Wavelength repeatability : ≤ 0.3 nm(single direction)
  • Baseline drift : ± 0.004 Abs / 30 min
Atomic Absorption Spectrophotometer LAAS-A13
  • Working spectral range : 190 to 900 nm
  • Spectral Bandwith : 0.1, 0.2, 0.4, 1.0 and 2.0 nm
  • Wavelength accuracy : ± 0.15 nm
  • Wavelength repeatability : ≤ 0.04 nm
  • Baseline stability : ≤ 0.002 Abs / 30 min
Atomic Absorption Spectrophotometer LAAS-A20
  • Wavelength range : 180 - 900 nm
  • Spectral Bandwidth : 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
  • Wavelength accuracy : ≤ 0.15 nm
  • Wavelength repeatability : ± 0.1 nm
  • Baseline drift : ≤ ± 0.002 Abs / 30 min (Static), ≤ ± 0.005 Abs / 30 min (Dynamic)
Atomic Absorption Spectrophotometer LAAS-A21
  • Wavelength range : 180 – 900 nm
  • Spectral Bandwidth : 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover)
  • Wavelength accuracy : ≤ 0.15 nm
  • Wavelength repeatability : ± 0.1 nm
  • Baseline drift : ≤ ± 0.002 Abs / 30 min (Static) ≤ ± 0.005 Abs / 30 mins (Dynamic)
Atomic Absorption Spectrophotometer LAAS-A22
  • Wavelength range : 180 – 900 nm
  • Spectral Bandwidth : 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting
  • Wavelength accuracy : ≤ 0.15 nm
  • Wavelength repeatability : ± 0.1 nm
  • Baseline drift : ≤ ± 0.002 Abs/30 min (Static) ≤ ± 0.005 Abs/30 min (Dynamic)
Double Beam UV-Vis Spectrophotometer LUS-B10
  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 1.8 nm
  • Optical System : Double beam
  • Wavelength Accuracy : ±0.3 nm
  • Wavelength Repeatability : ≤0.1 nm
Double Beam UV-Vis Spectrophotometer LUS-B11
  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 1.8 nm
  • Optical system : Double beam; 1200 lines/mm grating
  • Wavelength accuracy : ±0.1nm (D2 656.1nm), ±0.3nm @ all
  • Wavelength repeatability : 0.2 nm
Double Beam UV-Vis Spectrophotometer LUS-B12
  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 1.8 nm
  • Optical System : Double beam, C-T monochromator,1200 L/mm holographic grating
  • Wavelength Accuracy : ±0.3 nm
  • Wavelength Repeatability : 0.2 nm
Double Beam UV-Vis Spectrophotometer LUS-B13
  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 1.0 nm
  • Optical System : Double beam
  • Wavelength Accuracy : ±0.3 nm
  • Wavelength Repeatability : ≤0.1 nm
Double Beam UV-Vis Spectrophotometer LUS-B20
  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 1.0 to 5.0 nm (adjustable)
  • Optical system : Double beam, C-T monochromator, 1600 L/mm holographic grating
  • Wavelength accuracy : ±0.3 nm
  • Wavelength repeatability : 0.1 nm
Double Beam UV-Vis Spectrophotometer LUS-B40
  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 0.5/1/2/4 nm
  • Wavelength Accuracy : ± 0.1nm (D2, 656.1 nm), ± 0.3 nm full range
  • Wavelength Repeatability : ≤ 0.1 nm
  • Optical system : Double beam grating 1200 lines/mm
Double beam UV-Visible Spectrophotometer LUS-B15
  • Wavelength range : 190 ~ 1100 nm
  • Spectral bandwidth : 2 nm
  • Wavelength accuracy : 0.5 nm
  • Wavelength repeatability : ≤ 0.2 nm
  • Transmittance accuracy : ≤ 0.05 % T
Double Beam UV/Vis Spectrophotometer LUS-B16
  • Wavelength Range : 190 ~ 1100 nm
  • Setting Wavelength : Automatic
  • Spectral Bandwidth : 0.5 / 1.0 / 2.0 / 4.0 nm adjustable
  • Wavelength Accuracy : ± 0.3 nm
  • Wavelength Repeatability : ≤ 0.1 nm
Double Beam UV/Vis Spectrophotometer LUS-B30
  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 2 nm
  • Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
  • Wavelength Repeatability : ≤ 0.1 nm
  • Optical system : Double beam 1200 lines/mm
Double Beam UV/Vis Spectrophotometer LUS-B31
  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 1 nm
  • Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
  • Wavelength Repeatability : ≤ 0.1 nm
  • Optical system : Double beam 1200 lines/mm
Double Beam UV/Vis Spectrophotometer LUS-B32
  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 0.5/1/2/4/5 nm
  • Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
  • Wavelength Repeatability : ≤ 0.1 nm
  • Optical system : Double beam 1200 lines/mm
Flame Atomic Absorption Spectrophotometer LAAS-A12
  • Wavelength range : 190 nm ~ 900 nm
  • Spectral bandwidth : 0.1 nm, 0.2 nm, 1.0 nm, 2.0 nm
  • Wavelength accuracy : ± 0.25 nm
  • Wavelength repeatability : 0.15 nm
  • Temperature : 15 °C to 30 °C
Fluorescence Spectrophotometer LFS-A10
  • Light source : 150 W Xenon lamp
  • Excitation wavelength : 200 nm to 900 nm
  • Emission wavelength : 200 nm to 900 nm
  • Excitation slit : 2 nm, 5 nm, 10 nm, 20 nm
  • Emission slit : 2 nm, 5 nm, 10 nm, 20 nm
Fluorescence Spectrophotometer LFS-A11
  • Excitation Source : 150 W Xenon Lamp
  • Excitation Wavelength : 200 nm to 900 nm
  • Excitation Slit : 1 nm, 2 nm, 5 nm, 10 nm, 20 nm
  • Emission Slit : 1 nm, 2 nm, 5 nm, 10 nm, 20 nm
  • Wavelength Accuracy : ± 0.4 nm
Fluorescence Spectrophotometer LFS-A12
  • Light source : 150 W Xenon lamp
  • Excitation wavelength : 200 nm to 900 nm
  • Emission wavelength : 200 nm to 900 nm
  • Excitation slit : 2 nm, 5 nm, 10 nm, 20 nm
  • Emission slit : 2 nm, 5 nm, 10 nm, 20 nm
Nano Spectrophotometer LNS-A10
  • Wavelength range : 200 - 800 nm
  • Path length : 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
  • Wavelength accuracy : ± 1 nm
  • Wavelength Resolution : ≤ 3 nm (FWHM at Hg 546 nm)
  • Minimum Sample size : 0.5 - 2.0 µl
Nano Spectrophotometer LNS-A20
  • Wavelength range : 190 to 850 nm
  • Wavelength accuracy : ± 1 nm
  • Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
  • Cuvette details : Recyclable micro cuvette, 8.5 mm sample level height
  • Path length of cuvette : 1 mm, 2 mm, 5 mm, 10 mm
Nano Spectrophotometer LNS-A21
  • Wavelength range : 200 - 850 nm
  • Path length : 1 mm, 2 mm, 5 mm, 10 mm
  • Wavelength accuracy : ± 1 nm
  • Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
  • Minimum Sample size : 0.3 - 2.0 µl
Nano Spectrophotometer LNS-B11
  • Wavelength range : 230 nm, 260 nm, 280 nm
  • Path length : 1.0 mm, 0.2 mm
  • Minimum Sample size : 0.3 - 2.0 µl
  • Absorbance range : 0.2 - 75A (10 mm equivalent absorbance)
  • Absorbance precision : 0.002 Abs
Nano Spectrophotometer LNS-C10
  • Cuvette : No
  • PC : Inbuilt
  • Wavelength range : 190 - 850 nm
  • Path length : 1 mm, 0.2 mm ,0.04 mm
  • Wavelength accuracy : ± 1 nm
Nano Spectrophotometer LNS-C11
  • Cuvette : Yes
  • PC : Inbuilt
  • Wavelength range : 190 - 850 nm
  • Path length : 1 mm, 0.2 mm ,0.04 mm
  • Wavelength accuracy : ± 1 nm
Nano Spectrophotometer LNS-C12
  • Cuvette : Yes
  • Temperature : Room Temperature 42 ºC
  • PC : Inbuilt
  • Wavelength range : 190 - 850 nm
  • Path length : 1 mm, 0.2 mm ,0.04 mm
Nano Spectrophotometer LNS-C13
  • Cuvette : Yes
  • Temperature : 4 ºC - 42 ºC (Heating & Cooling)
  • PC : Inbuilt
  • Wavelength range : 190 - 850 nm
  • Path length : 1 mm, 0.2 mm ,0.04 mm
NIR Spectrophotometer LNIR-A10
  • Wavelength Range : 900 nm to 2500 nm
  • Wavelength Accuracy : ≤ 0.2
  • Wavelength Reproducibility : ≤ 0.05
  • Bandwidth : 8 nm
  • Measurement Mode : Transmission
Portable spectrophotometer LSP-A10
  • Illumination : d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability : Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
  • Sensor : Blue light enhanced sensor array
  • Size of integrated sphere : 40 mm, alvan diffused reflection surface coating
  • Illumination light source : CLED
Portable spectrophotometer LSP-A11
  • Illumination : d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability : Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),br/> Maximum:0.03
  • Sensor : Dual light path sensor array
  • Size of integrated sphere : 40 mm, alvan diffused reflection surface coating
  • Illumination light source : CLED
Portable spectrophotometer LSP-A12
  • Illumination : d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability : Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
  • Sensor : Photoelectric diode sensor
  • Size of integrated sphere : 40 mm, alvan diffused reflection surface coating
  • Illumination light source : CLED
Portable spectrophotometer LSP-A13
  • Illumination : d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability : Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.02(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.04
  • Sensor : Photoelectric diode sensor
  • Size of integrated sphere : 40 mm, alvan diffused reflection surface coating
  • Illumination light source : CLED
Portable spectrophotometer LSP-A20
  • Illumination : Observation angles 2°/10°
    Illumination: d/8 (Diffused lighting, 8° observation angle)
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability : Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.04
  • Sensor : Dual light path sensor array
  • Size of integrated sphere : 40 mm, alvan diffused reflection surface coating
  • Illumination light source : Pulse Xenon Lamp
Portable Spectrophotometer LSP-A30
  • Illumination : 45/0 (45 ring shaped illumination,0° observation angle)
  • Repeatability : Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
  • Sensor : High sensitivity silicon photodiode
  • Test angle : -
  • Test area : -
Portable Spectrophotometer LSP-A31
  • Illumination : 45/0 (45 ring shaped illumination,0° observation angle)
  • Repeatability : Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
  • Sensor : High sensitivity silicon photodiode
  • Test angle : 60°
  • Test area : 5 × 10 mm
Portable Spectrophotometer LSP-A40
  • Optical Geometry : D/8 (diffused illumination,8° viewing), Specular Component Included (SCI)
  • Integrating Sphere Size : Φ 40 mm
  • Light Source : LED (Full band balanced LED)
  • Color Spaces and Indices : Reflectance, CIE-Lab, CIE-LCh, Hunter Lab, CIE Luv, XYZ, Yxy, RGB, Colour difference (ΔE × ab, ΔE × cmc, ΔE × 94, ΔE × 00), WI (ASTM E313-00, ASTM E313- 73, CIE/ISO, AATCC, Hunter, Taube Berger Stensby), YI (ASTM D1925, ASTM E313-00, ASTM E313-73), Blackness (My,dM),Colour Fastness, Tint,(ASTM E313-00),Colour Density CMYK(A,T,E,M), Milm, Munsell, Opacity, Colour strength
  • Sensor : 256 pixel CMOS sensor
Portable Spectrophotometer LSP-A41
  • Optical Geometry : D/8 (diffused illumination,8° viewing), SCI (Specular Component Included), SCE (Specular Component Excluded)
  • Integrating Sphere Size : Φ 40 mm
  • Light Source : LED (Full band balanced LED)
  • Color Spaces and Indices : Reflectance, CIE-Lab, CIE-LCh, Hunter Lab, CIE Luv, XYZ, Yxy, RGB, Colour difference (ΔE × ab, ΔE × cmc, ΔE × 94, ΔE × 00), WI (ASTM E313-00, ASTM E313- 73, CIE/ISO, AATCC, Hunter, Taube Berger Stensby), YI (ASTM D1925, ASTM E313-00, ASTM E313-73), Blackness (My,dM),Colour Fastness, Tint,(ASTM E313-00),Colour Density CMYK(A,T,E,M), Milm, Munsell, Opacity, Colour strength
  • Sensor : 256 pixel CMOS sensor
Portable Spectrophotometer LSP-C10
  • Reflect : 8º(diffused illumination, 8 degree viewing angle)
  • Optical Geometry : SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source
  • Standards : ISO7724-1, ASTM E1164, DIN5033 Teil7
  • Integrating Sphere Size : Φ 40 mm
  • Light Source : Combined full spectrum LED light source, UV light source
Portable Spectrophotometer LSP-C11
  • Reflect : 8º(diffused illumination, 8 degree viewing angle)
  • Optical Geometry : SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source
  • Standards : ISO7724-1, ASTM E1164, DIN5033 Teil7
  • Integrating Sphere Size : Φ 40 mm
  • Light Source : Combined full spectrum LED light source, UV light source
Single Beam UV-Vis Spectrophotometer LUS-C10
  • Wavelength Range : 200 to 1000 nm
  • Spectral Bandwidth : 4.0 nm
  • Optical System : Single beam
  • Wavelength Accuracy : ±0.2 nm
  • Wavelength Repeatability : 0.2 nm
Single Beam UV/Vis Spectrophotometer LUS-A50
  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 2 nm
  • Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
  • Wavelength Repeatability : ≤ 0.1 nm
  • Optical system : Single beam 1200 lines/mm
Single Beam UV/Vis Spectrophotometer LUS-A51
  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 1 nm
  • Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
  • Wavelength Repeatability : ≤ 0.1 nm
  • Optical system : Single beam 1200 lines/mm
Single Beam UV/Vis Spectrophotometer LUS-A52
  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 0.5/1/2/4/5 nm
  • Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
  • Wavelength Repeatability : ≤ 0.1 nm
  • Optical system : Single beam 1200 lines/mm
Single Beam UV/Visible Spectrophotometer LUS-A10
  • Wavelength Range : 190 ~ 1100 nm
  • Spectral Bandwidth : 1 nm
  • Wavelength Accuracy : ± 0.3 nm
  • Wavelength Repeatability : 0.2 nm
  • Photometric Range : 0 - 200 % T, (-0.3) to (-3.0) A, 0 - 9999 C
Single Beam UV/Visible Spectrophotometer LUS-A11
  • Wavelength Range : 190 ~ 1100 nm
  • Spectral Bandwidth : 1.8 nm
  • Wavelength Accuracy : ± 0.3 nm
  • Wavelength Repeatability : 0.2 nm
  • Photometric Range : 0 - 200 % T, (-0.3) to (-3.0) A, 0 - 9999 C
Single Beam UV/Visible Spectrophotometer LUS-A20
  • Wavelength Range : 190 ~ 1100 nm
  • Setting Wavelength : Automatic
  • Spectral Bandwidth : 2 nm
  • Wavelength Accuracy : ± 0.5 nm
  • Wavelength Repeatability : ≤ 0.2 nm
Single Beam UV/Visible Spectrophotometer LUS-A21
  • Wavelength Range : 190 ~ 1100 nm
  • Setting Wavelength : Automatic
  • Spectral Bandwidth : 1.8 nm
  • Wavelength Accuracy : ± 0.3 nm
  • Wavelength Repeatability : ≤ 0.1 nm
Single Beam UV/Visible Spectrophotometer LUS-A22
  • Wavelength Range : 190 ~ 1100 nm
  • Spectral Bandwidth : 0.5 nm, 1 nm, 2 nm, 4 nm adjustable
  • Wavelength Accuracy : ± 0.3 nm
  • Wavelength Repeatability : ≤ 0.1 nm
  • Photometric Range : (-4)A to 4 A
Single Beam UV/Visible Spectrophotometer LUS-A30
  • Wavelength Range : 190 ~ 1100 nm
  • Setting Wavelength : Automatic
  • Spectral Bandwidth : 4 nm
  • Wavelength Accuracy : ± 0.5 nm
  • Wavelength Repeatability : ≤ 0.2 nm
Single Beam UV/Visible Spectrophotometer LUS-A40
  • Wavelength Range : 190 ~ 1100 nm
  • Spectral Bandwidth : 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm
  • Wavelength Accuracy : ± 0.3 nm
  • Wavelength Repeatability : 0.2 nm
  • Photometric Range : 0 - 200 % T, (-0.3) to (-3.0)A, 0 - 9999 C
Table top spectrophotometer LTS-A10
  • Illumination system : d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere : 40 mm, alvan diffused reflection surface coating
  • Illumination light source : CLED
  • Sensor : Dual light path sensor array
  • Light source : A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF
Table top spectrophotometer LTS-A11
  • Illumination system : d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere : 40 mm, alvan diffused reflection surface coating
  • Illumination light source : CLED
  • Sensor : Dual light path sensor array
  • Light source : A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF
Table top spectrophotometer LTS-A12
  • Illumination system : d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere : 15.2 cm, alvan diffused reflection surface coating
  • Illumination light source : CLED
  • Sensor : Dual light path sensor array
  • Light source : A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF
Table top spectrophotometer LTS-A13
  • Illumination system : d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement
  • Size of integrated sphere : 40 mm, alvan diffused reflection surface coating
  • Illumination light source : CLED
  • Sensor : Dual light path sensor array
  • Light source : A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF
Table Top Spectrophotometer LTS-A15
  • Wavelength Range : 400 nm to 700 nm
  • Wavelength Interval : 10 nm
  • Sensor : High sensitivity silicon photodiode
  • Light Source : LED
  • Working Temperature Range : 0 ℃ to 45 ℃
Table Top Spectrophotometer LTS-A16
  • Wavelength Range : 360 nm to 780 nm
  • Wavelength Pitch : 10 nm
  • Sensor : Silicon Photodiode Array
  • Grating Method : Concave Grating
  • Sphere Diameter : 152 mm
Vis Spectrophotometer LVS-A10
  • Wavelength Range : 330 to 1000 nm
  • Spectral Bandwidth : 5 nm
  • Wavelength Accuracy : ± 2 nm
  • Wavelength Repeatability : ≤ 1.0 nm
  • Photometric Range : T: 0 to199.9%, A: -0.3 to2.5 Abs, F; 0 to 9999, C: 0 to 9999
Vis Spectrophotometer LVS-A11
  • Wavelength Range : 335 ~ 1000 nm
  • Spectral Bandwidth : 4 nm
  • Wavelength Accuracy : ± 2 nm
  • Wavelength Repeatability : 1 nm
  • Photometric Range : T: 0 ~ 199.9 % , A: (-0.3) ~ 2.5A bs, F: 0 ~ 9999, C: 0 ~ 9999
Vis Spectrophotometer LVS-B10
  • Wavelength Range : 325 ~ 1000 nm
  • Setting Wavelength : Automatic
  • Spectral Bandwidth : 2 nm
  • Wavelength Accuracy : ± 1.0 nm
  • Wavelength Repeatability : ≤ 0.2 nm
Vis Spectrophotometer LVS-C10
  • Wavelength Range : 320 ~ 1100 nm
  • Spectral Bandwidth : 4 nm
  • Wavelength Accuracy : ± 0.5 nm
  • Wavelength Repeatability : ≤ 0.2 nm
  • Photometric Range : (-0.3) ~ 3 A
Vis Spectrophotometer LVS-C11
  • Wavelength Range : 320 ~ 1000 nm
  • Spectral Bandwidth : 2 nm
  • Wavelength Accuracy : ± 0.5 nm
  • Wavelength Repeatability : ≤ 0.2 nm
  • Photometric Range : (-0.3) ~ 3 A
Visible Spectrophotometer LVS-A20
  • Photometry : Single Beam
  • Monochromatic Type : Czerny-Turner
  • Wavelength range : 340 to 1000nm
  • Spectral bandwidth : 5 nm
  • Wavelength Accuracy : ± 2nm
Visible Spectrophotometer LVS-A21
  • Photometry : Single Beam
  • Monochromatic Type : Czerny-Turner
  • Wavelength range : 325 to 1000nm
  • Spectral bandwidth : 2 nm
  • Wavelength Accuracy : ± 2nm
Visible Spectrophotometer LVS-A30
  • Wavelength range : 320 to 1100 nm
  • Spectral bandwidth : 2.0 nm
  • Wavelength Accuracy : ± 0.8 nm
  • Wavelength Repeatability : ≤ 0.3 nm
  • Optical system : Single beam, blazed holographic Grating (1200 lines/mm)
Xenon Lamp Spectrophotometer LXLS-A10
  • Optical system : Double Beam, Grating 1200 lines/mm
  • Wavelength Range : 190 nm to 1100 nm
  • Spectral Bandwidth : 2 nm
  • Wavelength Accuracy : ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
  • Wavelength Repeatability : ≤ 0.1 nm
Xenon Lamp Spectrophotometer LXLS-A11
  • Optical system : Double Beam, Grating 1200 lines/mm
  • Wavelength Range : 190 nm to 1100 nm
  • Spectral Bandwidth : 1 nm
  • Wavelength Accuracy : ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
  • Wavelength Repeatability : ≤ 0.1 nm
Xenon Lamp Spectrophotometer LXLS-A13
  • Optical system : Double Beam, Grating 1200 lines/mm
  • Wavelength Range : 190 nm to 1100 nm
  • Spectral Bandwidth : 2 nm
  • Wavelength Accuracy : ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
  • Wavelength Repeatability : ≤ 0.1 nm
Xenon Lamp Spectrophotometer LXLS-A14
  • Optical system : Double Beam, Grating 1200 lines/mm
  • Wavelength Range : 190 nm to 1100 nm
  • Spectral Bandwidth : 1 nm
  • Wavelength Accuracy : ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
  • Wavelength Repeatability : ≤ 0.1 nm