Spectrometer

Angular Spectrometer LASM-A10
  • Angle Measurement Accuracy : 1inch
  • Optical Parameter :
    Focal Length 170 mm
    Effective Aperture Φ 22 mm
    Field of View 3° 22inch
    Focal Length of Telescope’s Eyepiece 24.3 mm
    Maximum Length Between Collimator and Telescope 120 mm
    Slit Width 0.02 to 2 mm
    Diopter Compensation Range ≥ ± 5 diopters
  • Divided Circle :
    Diameter Φ178 mm
    Circle Graduation 0° to 360°
    Division 0.5°
    Vernier Reading Value 1inch
  • Stage :
    Diameter Φ70 mm
    Rotating Range 360°
    Range of Vertical Adjustment 20 mm
  • Attachments :
    Prism Angle 60° ± 5inch
    Transformer 6.3 Ⅴ/220 Ⅴ (3 ⅤA)
    Planar Holographic Grating 300/ mm
Atomic Fluorescence Spectrometer LAFS-A10
  • Beam Configuration : Dual Channel
  • Elements ( Measuring Range ) :
    As, Se, Pb, Bi, Sb, Te, Sn < 0.01 µg/L
    Hg, Cd < 0.001 µg/L
    Zn < 1.0 µg/L
    Ge < 0.1 µg/L
  • Precision ( RSD ) : < 1.0
  • Linear range : More than 3 orders of magnitude
  • Lamp : Hollow cathode lamp
FTIR Spectrometer LIR-B10
  • Spectral Range : 7800 cm-1 to 350 cm-1
  • Resolution : 0.85 cm-1
  • Wave number precision : ± 0.01 cm-1
  • Scanning speed : Microprocessor control, different scanning speed selectable
  • Signal to Noise ratio : 20,000:1( RMS value 2100-1 to 2000-1 )
Handheld XRF Spectrometer LXRF-B10
  • Analytical Method : Energy dispersive X-ray fluorescence analytical Method
  • Elements Measuring : Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
  • Range : Simultaneous detector
  • Content measurement range : ppm to 100%
  • Detector : SDD detector, Simultaneous analysis 40 elements
Handheld XRF Spectrometer LXRF-B11
  • Analytical Method : Energy dispersive X-ray fluorescence analytical Method
  • Elements Measuring : Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
  • Range : Simultaneous detector
  • Content measurement range : ppm to 99.99%
  • Detector : SDD detector or fast SDD detector (optional)
ICP spectrometer LICP-A10
  • Wavelength range ( 3600 lines / mm ) : 180 to 500 nm
  • Wavelength range ( 2400 lines / mm ) : 180 to 800 nm
  • Temperature : 20 ~ 28 °C
  • Elements per minute : 26 elements
  • Humidity : 70%
ICP Spectrometer LICP-A11
  • Wavelength range : 180 to 900 nm
  • Elements per minute : 15 elements
  • Temperature : 29 °C
  • Incident slit : 25 µm
  • Standard deviation : RSD ≤ 2 %
ICP Spectrometer LICP-A12
  • Wavelength range : 195 to 800 mm
  • Elements per minute : 10 elements
  • Temperature range : 32 °C
  • Incident slit : 20 µm
  • Standard deviation : RSD ≤ 2 %
ICP Spectrometer LICP-B10
  • Monochromator Specifications :
    Optical type Czerny turner
    Resolution ≤ 0.015nm (3600 line grating)
    ≤ 0.030nm (2400 line grating)
    Focal length 1000 mm
    Grating specifications huge holographic grating with 3600 L/mil or 2400 L/mil and 80 mm × 100 mm of ruling area
    Wavelength range 195 to 500 nm for 3600 line grating
    195 to 800 nm for 2400 line grating
  • Solid State Power Specifications :
    Frequency 27.12 MHz
    Frequency stability: < 0.05%
    Spray chamber Scott double pass spray chamber
    Output power 800 W to 1600 W, adjustable with power efficiency more than 65%
    Output power stability ≤ 0.05%
    Induction coil 25 mm × 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)
  • Technical Specifications :
    Suitable sample content range Liquid sample: 0.01 ppm to several thousand ppm
    Solid or power sample: 0.001% to 70%
    Repeatability short-term stability- RSD ≤ 1.5%
    Long-term stability: RSD ≤ 2%
    Test speed 5 to 8 elements / min
    Limits of detection (LOD, µg/L) for most elements 1ppb to 10ppb
  • Control Circuit :
    Photomultiplier tube specification R212 / R928
    Negative high voltage -50 to -1000 V
    Circuit measuring range (10-12 to 10 -4) A
    Signal acquisition VF conversion
  • Working Environment :
    Temperature for storage and transportation 15°C to 25°C
    Humidity for storage and transportation ≤ 70%
    Power Stability 220 ± 10V; 50 to 60 V
    Humidity ≤ 70%
    Temperature 15°C to 30°C
XRD Diffractometer LXRD-A10
  • X-ray Tuble : Glass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kW
  • Focus Size : 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mm
  • Stability : ≤ 0.01 %
  • Tube Current : 5 to 80 mA
  • Tube Voltage : 10 to 60 kV
XRF-Spectrometer LXRF-A10
  • Measureable elements : S to U
  • Detection limit : 1 ppm
  • Temperature : 15 ~ 30 °C
  • Elemental content : 1 ppm to 99 %
  • Repeatability : 0.001