Download Catalog for Gas Chromatography LGC-B11

Gas Chromatography LGC-B11

Gas Chromatography LGC-B11

www.labtron.us | info@labtron.us

Overview

Gas Chromatography LGC-B11 is a benchtop unit with advanced flow controller (AFC) technology. System has digital control mode and polar capillary columns to separate polar analytes. GC oven is capable of 9 temperature program ramps and hold steps, and features rapid cooling: 250 °C to 50 °C < 10 minutes. Accurate flow rate control via AFC has higher level repeatability of retention time and peak area, enabling specific level of analysis by means of dual FID detectors.

Specifications :
Oven
Maximum capacity 22 L
Temperature range RT + 5 ℃ to 400 ℃
Temperature accuracy ± 0.1 ℃
Temperature program 9-phase/ 10 platform
Program total time 9999.9 min
Maximum temperature heating rate 0.1 to 60 ℃/ min
Maximum cooling rate ˂ 10 mins (250 to 50 ℃)
Sample injector
Temperature range RT+ 7 ℃ to 420 ℃
Temperature control Automatic
Injector type Column or split
Maximum sample inlet 3 pcs
Carrier gas flow type Constant pressure
Pre column pressure range 0 to 400 kPa
Pre column pressure accuracy 0.1 kPa
Mobile phase flow range H2: 0 to 200 ml/min, N2: 0 to 150 ml/min
Detector
Temperature range RT + 7 ℃ to 420 ℃
Maximum installation Dual detector
Flame ignition mode Automatic
Flame Ionization Detector (FID) Logarithmic amplifier
High voltage switch control
Baseline signal display
Ignition coil control
Detection limit: ≤3 ×10 to 12 g/s (Sample: n-hexadecane)
Baseline noise: ≤ 5 × 10 - 14 A
Baseline draft: ≤ 6 × 10 -13 A
Dynamic range: 10 7
RSD: ≤ 3 %
Power supply AC 220 V ± 22 V, 50 Hz ± 0.5 Hz, 3000 W
Packing dimension 1020 × 660 × 740 mm
Gross Weight 82 kg
Net weight 70 kg
Features :
  • -  7-inch LCD display specifies temperature, gas flow and heating curve
  • -  H2 and N2 mobile gas phase with AFC and constant pressure gas flow type
  • -  Equipped with capillary analysis system and capillary split sampler
  • -  Injection system incorporates diaphragm cleaning, split flow and auxiliary gas adjustment
  • -  Standard unit for high-speed analysis with polar capillary column
  • -  PEG-20M and FFAP stationary phase polar capillary columns can be coupled
  • -  Dual FID detector with automatic flame ignition and baseline signal display
  • -  Self-diagnostic and automatic fault recognition function
  • -  Multi-core and 32-bit embedded hardware system ensures the reliable operation
  • -  Equipped with chromatography workstation software to process data
  • -  Memory function can store 20 sample test data
  • -  RS232 interface and LAN port
Applications :

Suitable for analysis of trace toxic compounds, monitoring and research in environmental protection, atmosphere and water source pollution. It is widely used for petrol-chemistry, environmental protection, epidemic prevention, pharmacology and scientific research.

Standard Accessories :

Accessories no Accessories name
1.        FID detector system
2.        Capillary injection system
3.        Chromatography workstation software

Optional Accessories :

Accessories no Accessories name
1 Polar capillary columns PEG-20M
Stationary phase: 30 m × 0.32 mm
injector temperature: 250 ℃
Oven temperature: 165 ℃
Detector: FID- 250 ℃
Inlet pressure: 0.04 Mpa
2 Polar capillary columns FFAP
Stationary phase: 30 m × 0.32 mm
Injector temperature: 250 ℃
Oven temperature: 165 ℃
Detector: FID- 250 ℃
Inlet pressure: 0.04 Mpa
3 Syringe 1 ul
4 Syringe 5 ul

Labtron