ICP Spectrometer LICP-B10 is an instrument which measures elements in ppb levels with least interference and reduces the time taken for analysis by detecting 5 to 6 elements in 1 min. Excellent analytical precision, high optical resolution, fully automated, wide wavelength range with 2400 line grating, powerful analysis software, high performance solid-state RF system, high accuracy etc. are some of the characteristic features. The equipment consist of a Scott-type spray chamber, quartz torch, spectrophotometer with Czerny-Turner monochromator, detector with photomultiplier tube and data processing system which allows multi-element measurement along with high resolution. It finds applications in environmental, food safety, metallurgy, pharmaceutical etc. fields.
Specifications :
| Monochromator Specifications |
| Optical type |
Czerny turner |
| Resolution |
≤ 0.015nm (3600 line grating) ≤ 0.030nm (2400 line grating) |
| Focal length |
1000 mm |
| Grating specifications |
huge holographic grating with 3600 L/mil or 2400 L/mil and 80 mm × 100 mm of ruling area |
| Wavelength range |
195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating |
|
| Solid State Power Specifications |
| Frequency |
27.12 MHz Frequency stability: < 0.05% |
| Spray chamber |
Scott double pass spray chamber |
| Output power |
800 W to 1600 W, adjustable with power efficiency more than 65% |
| Output power stability |
≤ 0.05% |
| Induction coil |
25 mm × 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter) |
|
| Technical Specifications |
| Suitable sample content range |
Liquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70% |
| Repeatability |
short-term stability- RSD ≤ 1.5% Long-term stability: RSD ≤ 2% |
| Test speed |
5 to 8 elements / min |
| Limits of detection (LOD, µg/L) for most elements |
1ppb to 10ppb |
|
| Control Circuit |
| Photomultiplier tube specification |
R212 / R928 |
| Negative high voltage |
-50 to -1000 V |
| Circuit measuring range |
(10-12 to 10 -4) A |
| Signal acquisition |
VF conversion |
|
| Working Environment |
| Temperature for storage and transportation |
15°C to 25°C |
| Humidity for storage and transportation |
≤ 70% |
| Power Stability |
220 ± 10V; 50 to 60 V |
| Humidity |
≤ 70% |
| Temperature |
15°C to 30°C |
|
| Other Details |
| Packaging Dimension and Gross Weight (4 case) |
1st case: 188 × 111 × 105 / 348 kg 2nd case: 60 × 60 × 55 / 25 kg 3rd case: 59 × 67 × 97 / 80 kg 4th case: 38.5 × 38.5 × 63 / 47 kg |
|
Features :
- - Highly advance optical design
- - Holographic grating for minimum scattering of light
- - Correction of spectral interference to improvise detection
- - System controlled torch movement for optimized position
- - System controlled mass flow controller for carrier gas, auxiliary gas and plasma gas
- - 27.12 MHz RF generator for efficient ionization
- - Auto-coupling system
- - Peristaltic pump for stable flow rate and drainage of sample
- - Argon gas cylinder last up to 8 hours
- - Auto-sampler can be provided
- - Software Details
- - Allows selection of multiple elements and parameters for analysis
- - Faster Calibration function
- - Correction of background interference
- - Report generation with single button press
- - Many export options
- - Real-time graphical display of instrument status
- - Plasma ignition with one button press
- - Large database to select spectral lines according to requirement
Applications :
It used for quantitative and qualitative analysis of elements in the given sample. Various fields like petrochemicals, pharmaceuticals, agriculture, environmental, food industry, metallurgy, processing industry etc. require it for several operations.
Standard Accessories :
| Accessories No |
Accessories Name |
| 1 |
Gas pressure regulator |
| 2 |
Water cooling system |
| 3 |
Voltage stabilizer |
| 4 |
ICP 2060T power cable |
| 5 |
Copper cable for ground |
| 6 |
Sampling system: nebulizer, spray chamber, plasma torch |
Optional Accessories :
Auto-sampler