Enquiry Form

info@labtron.us

Download Catalog for TSS Meter LTSS-A10

TSS Meter LTSS-A10

TSS Meter LTSS-A10

www.labtron.us | info@labtron.us

Overview

TSS meter LTSS-A10 is a tabletop meter with a dual-beam infrared scattered light photometer detection system for enhanced stability. Built-in self-diagnosis function to ensure data accuracy. Optional cleaning brush for automate cleansing function to reduce the sensor maintenance.

Specifications :
Measurement range 20000 mg/L
0.01 mg/L ~ 45000 mg/L
0.01 mg/L ~ 120000 mg/L
Measurement accuracy ± 2 % F.S. of its range ( Depending on the homogeneity of sludge)
Pressure range ≤ 0.4 Mpa
Flow rate ≤ 2.5 m/s, 8.2 ft./s
Calibration Sample calibration
Slope calibration
Main material SUS316L
Titanium alloy marine
Cover : PVC
Cable : PVC
Power supply 9 V ~ 36 V DC
Communication protocol RS485
Storage temperature -15 °C to 65 °C
Measuring temperature 0 °C to 60 °C
Protective rate IP68
Cable length Standard : 10 m (maximum may be extended to 100 m)
Dimensions ( D x L ) 60 mm x 256 mm
Weight 1.65 kgs
Features :
  • -  “Dual-beam infrared scattered light photometer detection
  • -  Eliminates effects of sample color
  • -  Optional cleaning brush for automatic cleaning function
  • -  Digital sensor and high anti-jamming capacity
  • -  Standard digital signal output (integration and networking with other equipment without controller)
  • -  Plug-and-play sensors
  • -  Automatic temperature compensation
  • -  Automatic range selection”
Applications :

Used to check sludge concentration of technological process of sewage treatment plant, for online monitoring of industrial process water and suspended solids (sludge concentration) of waste water treatment process

Labtron