Overview
Analytical HPLC-A7832 system is equipped with a flow rate range of 0.0001 to 10 ml per minute. Integrated with a single and dual wavelength UV-Vis detector with a range of 190 to 800 nm that analyzes sample’s absorption at different wavelengths and a high pressure pump providing continuous consistent flow. Built in column heater provides reproducible retention time.
Specifications :
| Detector Specifications |
| Model No |
HPD-A20 |
HPD-A21 |
| Wavelength range |
Single wavelength ( 190 to 800 nm ) |
Dual wavelength ( 190 to 800 nm ) |
| Wavelength accuracy |
± 0.5 nm |
± 2 nm |
| Wavelength repeatability |
0.15 nm |
0.3 nm |
| Band width |
8 nm |
8 nm |
| Optical path |
10 nm |
10 nm |
| Deuterium lamp |
190 to 400 nm |
190 to 400 nm |
| Tungsten lamp |
400 to 800 nm |
400 to 800 nm |
| Baseline noise ( Static ) Au |
≤ ± 0.35 × 10-5 |
≤ ± 0.5 × 10-5 |
| Baseline drift ( Static ) Au / h |
≤ 1 × 10-4 |
≤ 1.5 × 10-4 |
| Minimum detection limit |
≤ 4 × 10-8 |
≤ 4 × 10-8 |
| Power |
100 W |
100 W |
| Power supply |
90 V / 50 to 60 Hz |
90 V / 50 to 60 Hz |
| Dimension |
460 × 315 × 180 mm |
460 × 315 × 180 mm |
| Weight |
9.5 kg |
9.5 kg |
|
| Pump Specifications |
| Flow rate range | 0.0001 to 10 ml / min | | Maximum pressure | 50 MPa , 0 to 2 ml / min | | Column size | 4.6 × 250 mm | | Sample size | 5 µm | | Pressure pulsation | ≤ 1 % at 10 MPa | | Flow rate accuracy | ± 0.15 % at 1 ml / min | | Flow rate repeatability % | ≤ 0.1 | | Gradient accuracy % | ± 1.5 | | Gradient repeatability % | ≤ 0.2 | | Dimension | 460 × 310 × 180 mm | | Power supply | 90 V | | Weight | 11.6 kg | |
Features :
- - Compression compensation ensuring gradient repeatability
- - Low pressure gradient
- - Detector ( Deuterium or tungsten lamp )
- - Automatic sample injector ( Autosampler )
- - 10 point calibration pump for linear pressure control
- - Error alarm function for over pressure ,under pressure and leakage
Applications :
Used in pharmaceutical analysis, food nutrient analysis of amino acids and sugars, detection of food contaminants, environmental pollutant and chemical product purity analysis
Standard Accessories :
| Accessory |
Quantity |
| Pump |
2 |
| UV-Vis detector ( without flow cell ) |
1 |
| Analytical flow cell |
1 |
| Injection valve |
1 |
| 20 μl sample loop |
1 |
| 4.6 × 250 mm ( 5 µm ) analytical column |
1 |
| Solvent tray |
1 |
| Binary gradient kit |
1 |
| Mixing chamber |
1 |
Optional Features :
| Accessory |
Quantity |
| Autosampler |
1 |
| Fraction collector |
1 |
| Column oven |
1 |