Enquiry Form

info@labtron.us
Gas Chromatography LGC-B11

Gas Chromatography LGC-B11

Gas Chromatography LGC-B11 is a benchtop unit with advanced flow controller (AFC) technology. System has digital control mode and polar capillary columns to separate polar analytes. GC oven is capable of 9 temperature program ramps and hold steps, and features rapid cooling: 250 °C to 50 °C < 10 minutes. Accurate flow rate control via AFC has higher level repeatability of retention time and peak area, enabling specific level of analysis by means of dual FID detectors.

Catalog

Specifications

Oven
Maximum capacity 22 L
Temperature range RT + 5 ℃ to 400 ℃
Temperature accuracy ± 0.1 ℃
Temperature program 9-phase/ 10 platform
Program total time 9999.9 min
Maximum temperature heating rate 0.1 to 60 ℃/ min
Maximum cooling rate ˂ 10 mins (250 to 50 ℃)
Sample injector
Temperature range RT+ 7 ℃ to 420 ℃
Temperature control Automatic
Injector type Column or split
Maximum sample inlet 3 pcs
Carrier gas flow type Constant pressure
Pre column pressure range 0 to 400 kPa
Pre column pressure accuracy 0.1 kPa
Mobile phase flow range H2: 0 to 200 ml/min, N2: 0 to 150 ml/min
Detector
Temperature range RT + 7 ℃ to 420 ℃
Maximum installation Dual detector
Flame ignition mode Automatic
Flame Ionization Detector (FID) Logarithmic amplifier
High voltage switch control
Baseline signal display
Ignition coil control
Detection limit: ≤3 ×10 to 12 g/s (Sample: n-hexadecane)
Baseline noise: ≤ 5 × 10 - 14 A
Baseline draft: ≤ 6 × 10 -13 A
Dynamic range: 10 7
RSD: ≤ 3 %
Power supply AC 220 V ± 22 V, 50 Hz ± 0.5 Hz, 3000 W
Packing dimension 1020 × 660 × 740 mm
Gross Weight 82 kg
Net weight 70 kg

Features

Applications

Suitable for analysis of trace toxic compounds, monitoring and research in environmental protection, atmosphere and water source pollution. It is widely used for petrol-chemistry, environmental protection, epidemic prevention, pharmacology and scientific research.

Standard Accessories

Accessories no Accessories name
1.        FID detector system
2.        Capillary injection system
3.        Chromatography workstation software

Optional Accessories

Accessories no Accessories name
1 Polar capillary columns PEG-20M
Stationary phase: 30 m × 0.32 mm
injector temperature: 250 ℃
Oven temperature: 165 ℃
Detector: FID- 250 ℃
Inlet pressure: 0.04 Mpa
2 Polar capillary columns FFAP
Stationary phase: 30 m × 0.32 mm
Injector temperature: 250 ℃
Oven temperature: 165 ℃
Detector: FID- 250 ℃
Inlet pressure: 0.04 Mpa
3 Syringe 1 ul
4 Syringe 5 ul