Specifications
| Wavelength Range | 360 nm to 780 nm |
|---|---|
| Wavelength Pitch | 10 nm |
| Sensor | Silicon Photodiode Array |
| Grating Method | Concave Grating |
| Sphere Diameter | 152 mm |
| Half Band Width | 5 nm |
| Reflectance Range | 0 to 200 % |
| Resolution | 0.0001 |
| Light Source |
Pulse Xenon Lamp LED |
| UV Measurement | Include UV, 400nm cut, 420nm cut, 460nm cut |
| Operating Temperature | 5 ℃ to 40 ℃ |
| Storage Temperature | -20 ℃ to 45 ℃ |
| Relative Humidity | 80 % RH (at 35 ℃) |
| Measurement Time |
SCI/SCE < 2 SCI+SCE < 4s |
| Measurement Aperture |
Reflectance: XLAV Φ30mm LAV 18mm,MAV Φ11mm SAV Φ6mm Transmittance:Φ25mm (Auto aperture size recognition) |
| Viewing Angles | 2° and 10° |
| Transmittance Sample Size |
No limit on sample width and height Thickness ≤ 50mm |
| Repeatability |
XLAV Spectrum Reflectance/Transmittance: standard deviation within 0.1% XLAV Chromaticity value: Standard deviation within ΔE*ab 0.015 * When a white calibration plate is measured 30 x at 5-second intervals after white calibration |
| Inter-Instrument Agreement | XLAV ΔE*ab 0.15 (BCRA Series II, Average measurement of 12 tiles, at 23℃) |
| Illuminants | A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,DLF,NBF,TL83,TL84 |
| Display | Reflectance and Transmittance graph/value, color value, color difference values, pass/fail, color simulation, color assessment, haze, liquid chromaticity values, color tendency |
| Color Spaces | L*a*b, L*C*h, Hunter Lab, Yxy, XYZ |
| Color Difference | ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc, ΔE*94, ΔE*00, ΔE*ab(hunter),555 shade sort |
| Other Indices | WI(ASTM E313-00,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Stensby),YI(ASTM D1925,ASTM E313-00,ASTM E313-73),Tint(ASTM E313-00),Metamerism index milm, stain fastness, color fastness, ISO brightness, R457, A density, T density, E density, M Density, APHA/Pt-Co/Hazen, Gardner, Saybolt, ASTM color, Haze, Total Transmittance, Opacity, Color Strength |
| Other Functions |
1. Camera to view measurement area 2. Support horizontal, vertical and downward measurement method (need optional accessories to support for downward measurement) 3. Auto humidity and temperature compensation function |
| Illumination/ Viewing System | Reflection: d/8(Diffused illumination, 8 degree viewing) Simultaneous measurement of SCI/SCE (ISO7724/1, CIE No.15, ASTM E1164, ASTM-D1003-07, DIN5033 Teil7,JIS Z8722 Condition C standard) Transmittance d/0(Diffused illumination, 0 degree viewing ) |
| Interface |
USB USB-B RS-232 |
| Screen Size | 7 Inches Touch Screen |
| Storage Memory | 8 GB U Disk for data storage and transfer |
| Power | 12V/3A |
| Dimensions (L × W × H) | 430 × 240 × 260 mm |
| Weight | 10.8 kg |
Features
Standard Accessories
| No | Accessory name | Remarks |
| 1 | Power Adaptor | |
| 2 | USB Cable | |
| 3 | fixture for transmittance | |
| 4 | U disk | PC software |
| 5 | Black Calibration Cavity | |
| 6 | White and Green Calibration Tile | |
| 7 | 0% Calibration Tile | Measure transmittance |
| 8 | Reflectance Test Support | |
| 9 | 30mm,18mm,11mm and 6mm apertures | |
| 10 | reflectance sample fixture | |
| 11 | Glass Cell | Size: 40 mm × 10mm |
Optional Accessories
| No | Accessory name |
| 1 | Heating Fixture for Transmittance |
| 2 | Vertical Support and Pneumatic ram for downward measurement |
| 3 | Reflectance fixture for small size sample |
| 4 | Reflectance Glass Cell Support |
| 5 | Corrosion-Resistant Protective Plate (non-removable), |
| 6 | Sample Holder for Fiber |
| 7 | Film Fixture |
| 8 | Transmittance Fixture for Small Aperture |
| 9 | Trolley Case |
| 10 | European Standard Plug |
| 11 | American Standard Plug |
Applications