Enquiry Form

info@labtron.us

Portable Multi Parameter Water Quality Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable Multi-parameter Water Quality Meter LMPWM-A10

  • pH mode :
    pH measurement range (-2.000) to 20.000 pH
    pH accuracy ± 0.002 pH
    pH calibration points 1 - 5 points
    pH calibration solutions USA, NIST, DIN or user defined
  • ORP measurement :
    ORP measurement range -1999.9 to 1999.9 mV
    ORP accuracy ±0.2 mV
    ORP calibration points 1 point
    ORP calibration solutions mV & relative mV
  • Ion measurement :
    Ion measurement range 0 to 19999 ppm, mg/L, mol/L
    Ion accuracy ± 0.5 % F.S. (monovalent), ± 1 % F.S. (divalent)
    Ion calibration points 2 - 5 points
    Ion calibration solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol/L, mg/L
  • Conductivity measurement :
    Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
    Conductivity accuracy ± 0.5 % F.S.
    Conductivity calibration points 1 - 5 points
    Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
    Temperature coefficient 0.0 to 10.0 % / °C
    Compensation modes Linear or pre water
    Cell constant K = 0.1, 1, 10 or user-defined
    Normalization temperature 20 °C or 25 °C
  • TDS measurement :
    TDS range 0 to 100 ppt. (max. 200 ppt., depending on factor setting)
    TDS accuracy ± 1 % F.S.
    TDS factor 0.1 - 1.0 (default 0.5)

Portable Multi-parameter Water Quality Meter LMPWM-A11

  • pH mode :
    pH measurement range (-2.000) to 20.000 pH
    pH accuracy ± 0.002 pH
    pH calibration points 1 - 5 points
    pH calibration solutions USA, NIST, DIN or user defined
  • ORP measurement :
    ORP measurement range -1999.9 to 1999.9 mV
    ORP accuracy ±0.2 mV
    ORP calibration points 1 point
    ORP calibration solutions mV & relative mV
  • Ion measurement :
    Ion measurement range
    Ion accuracy
    Ion calibration points
    Ion calibration solutions
  • Conductivity measurement :
    Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
    Conductivity accuracy ± 0.5 % F.S.
    Conductivity calibration points 1 - 5 points
    Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
    Temperature coefficient 0.0 to 10.0 % / °C
    Compensation modes Linear or pre water
    Cell constant K = 0.1, 1, 10 or user-defined
    Normalization temperature 20 °C or 25 °C
  • TDS measurement :
    TDS range 0 to 100 ppt. (max. 200 ppt., depending on factor setting)
    TDS accuracy ± 1 % F.S.
    TDS factor 0.1 - 1.0 (default 0.5)

Portable Multi-parameter Water Quality Meter LMPWM-A20

  • pH mode :
    pH measurement range (-2.000) to 20.000 pH
    pH accuracy ± 0.002 pH
    pH calibration points 1 - 5 points
    pH calibration solutions USA, NIST, DIN or user defined
  • ORP measurement :
    ORP measurement range -1999.9 to 1999.9 mV
    ORP accuracy ±0.2 mV
    ORP calibration points 1 point
    ORP calibration solutions mV & relative mV
  • Conductivity measurement :
    Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
    Conductivity accuracy ± 0.5 % F.S.
    Conductivity calibration points 1 - 5 points
    Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
    Temperature coefficient 0.0 to 10.0 % / °C
    Compensation modes Linear or pre water
    Cell constant K = 0.1, 1, 10 or user-defined
    Normalization temperature 20 °C or 25 °C
  • TDS measurement :
    TDS range 0-100 ppt. (max. 200 ppt., depending on factor setting)
    TDS accuracy ± 1 % F.S.
    TDS factor 0.1 - 1.0 (default 0.5)
  • Temperature compensation : 0 to 100 °C, 32 to 212 °F, Manual or Automatic
Portable Multi-parameter Water Quality Meter LMPWM-A21
  • pH mode :
    pH measurement range (-2.000) to 20.000 pH
    pH accuracy ± 0.002 pH
    pH calibration points 1 - 5 points
    pH calibration solutions USA, NIST, DIN or user defined
  • ORP measurement :
    ORP measurement range -1999.9 to 1999.9 mV
    ORP accuracy ±0.2 mV
    ORP calibration points 1 point
    ORP calibration solutions mV & relative mV
  • Dissolved oxygen :
    DO concentration range 0.00 to 20.00 mg/L
    DO accuracy ± 0.2 mg/L
    Calibration points 1 - 2 points
    Pressure correction 60.0 to 112.5 kPa, 450 - 850 mmHg
    Salinity correction 0 to 50 g/L
    % Saturation of Oxygen 0.0 to 200.0 %
    Accuracy ± 2.0 %
  • Temperature compensation : 0 to 100 °C, 32 to 212 °F, Manual or Automatic
  • Stability conditions : Low or high